Learn Detector Code - Response SL5 Installation & Operating Manual

36 zone wireless security system
Table of Contents

Advertisement

LEARN
DETECTOR CODE
(zones 1-32 only).
Allows a wireless detectors ID code to be learnt and
linked to the selected wireless zone.
3.1 Znn: xxxxx
Edit->Enter
3.1 Znn: xxxxx
1->Del
Learn->3
xxxxx = PIR, MAG or Smoke, empty
1 = Delete or
3 = Learn
1 = Delete
Confirm Delete
YES->1
3->NO
press 1 to confirm delete
press 3 to cancel
15s time-out or auto cancel
NO
Delete confirmed
within 15s?
YES
Device Deleted
Wait...
display for 3s
Linking a
New Detector to the Zone:
Note: There can only be one detector on each
zone so if a detector is already linked then linking
a new detector will replace the existing one.
To learn a new detector ID code and link it to the
selected zone press
The panel will now listen for a valid signal from
a new detector to link to the zone.
The Panel will remain in Learn Mode for
30s. If a valid signal is not received from a
new detector within 30s it will automatically
exit Learn Mode and return to the top of
level 3.1.
Activate the Tamper Switch on the PIR / MAG
detector or trigger a smoke detector via its
test button.
40
Send Code
waiting 30s...
Signal
received within 30s
NO
from detector not
yet linked to
any zone?
YES
New Device
xxxxx
display for 3s
Resend Code
waiting 15s...
Detector code
NO
confirmed within
15s?
Device Confirmed
xxxxx
display for 3s
Saving
New Device
display for 3s
3
.
Note: If
the detector is already linked
to the control panel on any other zone
then the panel will produce a single long
beep and the received signal from the
detector will be ignored.
If the detector is new and not already linked
on any security zone the panel will produce
two short beeps and the display will show
'New Device'
and the type or the detected
device; (e.g. PIR, MAG or Smoke).
Confirm the new device ID code by activating
the Tamper Switch on the same new PIR / MAG
detector or triggering the same smoke detector
with its test button within 15s.
Note: If
the confirmation signal is not
received within 15s the control panel will
produce a single long beep and exit the
learning process. The learning process
will need to be started again to learn the
new device into memory.
The panel will produce three short beeps
and the LCD will show 'Device
The LCD will then show 'Saving New
Device' while the ID code of the new
detector is stored into memory.
Deleting an Existing
If
a detector is already linked then the display
will show the detector type, for example:
'3.1 Zxx: PIR'.
The detector can be removed
from the system and its ID code erased from
memory without replacing it as follows:
To delete the current detector from the zone
1
press
.
1
Press
again within 15s to confirm and
actually delete the device.
The display will now show
Note: If
delete all is not confirmed within
15s then the action will be cancelled and the
device will not be deleted and the display will
revert to level 3.1 as before.
Confirmed'.
Device:
'3.1 Zxx: empty'.