The wired contact should be connected using
a maximum length of 1.5 metres of any of
the following:
– 6 core alarm cable
– 2 core bell wire (6 x 0.2mm minimum)
– 2 core 24AWG wire
A cable entry cut-out is provided beside the
terminal block in the battery cover.
6.
Switch SW3 is used to enable / disable the
internal / external wired magnetic contact.
Location of
Key-hole Screw
(underside)
Terminal Block for
Additional Wired
Magnetic Contact
Hole for
Mounting
Screw
Position of SW3
INT.
INT./EXT.
7.
Set the magnetic contact detector by setting the
position of the switch (SW3).
SW2
INT./EXT.
Switch SW3
INT. Position
If setting to the INT. position, only the internal
contact will be active. When two contacts are in
use for internal and external connection
16
7mm
8mm
Tamper
Switch
SW2
Switch
INT./EXT.
SW3
Function
Internal Contact ON
Internal and External
Contacts ON
SW2
INT./EXT.
Switch SW3
INT./EXT. Position
simultaneously (INT./EXT. position), only one
activation will be counted if one of the contacts is
opened. If one contact is left open and the other
closed contact is opened then an activation will
be counted.
If using external contacts wired to the Detector,
set to the INT./EXT. position.
IMPORTANT: If not using external contacts,
set to the INT. position for the Detector to
operate correctly.
8.
Refit the battery cover.
TESTING THE DOOR / WINDOW
DETECTOR
9.
Remove battery cover to activate the tamper switch.
As the button is released the LED indicator will
illuminate for approximately 1 second to show
that the tamper switch has been triggered and a
signal is being transmitted.
10. Open the door/window to remove the Magnet
from the Detector.
As the Magnet is moved away from the Detector
the LED indicator will illuminate for
approximately 1 second to show that the
Detector has been triggered and a signal is
being transmitted.
Note: It does not matter if the LED indicator
illuminates as the magnet is brought towards
the detector.
IMPORTANT: With the battery cover fitted the
LED indicator will not flash when the door /
window is opened, (unless the battery is low).
11. In order to communicate with the Control Panel,
the ID code of the Detector needs to be learnt
by the Control Panel. By pressing the tamper
switch either located adjacent to the PCB or the
rear cover of the Detector will emit the ID code
subject to the Control Panel being placed in Learn
Mode. See LEARNING ZONE DETECTORS on
the next page.
12. Refit the battery cover.