TROUBLE SHOOTING

Symptom /
Recommendation
Control Unit not working - Power LED OFF
or flashing.
1. Mains
power failure - check if other electrical
circuits are operable.
2.
Check that mains adaptor is plugged in and
socket is switched ON.
3.
Check that DC jack plug from mains adaptor is
connected in Control Panel.
4.
Check fuse / MCB in Consumer Unit on the
circuit serving the Control Panel.
Note:
Before replacing any fuses or resetting
the MCB, the cause of the failure should be
investigated and rectified.
Control Unit "Low Battery" LED flashing.
1.
Check all PIR, Door / Window, Remote, Keypad
and Smoke Detectors for low battery indication,
(i.e. LED behind detection lens flashes when
movement detected). Renew batteries as
required.
Control Unit not accepting User Access Code.
1.
Pause between key depressions too long. Do
not pause for more than 5 seconds between
pressing keys.
2.
Incorrect code entered. Press
re-entering correct code.
3.
Reset to factory defaults and reprogram system.
Detection Zone
triggered (LED flashing) but
no alarm is sounding.
1.
Entry / Exit delay still running and not yet
expired.
2.
Alarm duration period has already expired and
system has reset.
3.
Alarm duration programmed to 'no alarm'.
before
ESC
Siren and Indicator LEDs operating but no
alarm at Control Panel.
1.
Siren's Tamper switch activated. Check security
of Siren fixing to wall and adjustment of anti-
tamper switch to ensure switch is fully depressed.
Siren not responding to Control Panel.
1.
Ensure 'ID Code' of the Siren is learnt by the
Control Panel.
2.
Ensure main Siren configuration switch is set to
SIREN.
3.
Incorrect User Access Code being entered at
Control Panel.
4.
Ensure Siren is within effective radio range of
Control Panel and equipment is not mounted
close to metal objects.
5.
Siren rechargeable battery discharged
a. Clean Solar Panel.
b. Check age of rechargeable battery - replace if
at end of useful life.
c. Fit new initial power-up battery and re-power
up Siren.
Full
Alarm sounds when system has not
been triggered by an intruder or is disarmed.
1.
Tamper switch activation
a. Check all detector battery covers to ensure
correctly fitted.
b. Check Control Panel and Siren are securely
mounted to the wall and Tamper switch is
closed.
2.
Personal Attack Alarm operated from a Remote
Control or Control Panel.
3.
Jamming Detection circuit operated.
59