To adjust the PCB position simply slide it up and
down ensuring that the location legs are aligned
with the required position number marked on the
board.
7. To refit the PIR detector to the rear cover, offer
the detector up to the wall bracket and locate the
clips in the top edge into the rear cover. Push the
lower edge of the detector into place and refit the
fixing screw in the bottom edge of the PIR to
secure in position. Do not over-tighten the fixing
screws as this may damage the casing.
CONFIGURING THE PIR MOVEMENT
DETECTORS
Located on the PCB of the PIR Detector are two
blocks of DIP switches (labelled SW2 and SW3).
1. DIP switches 1 - 8 of SW2 are used to set the
House Code for the PIR Detector and must be set
to the same ON/OFF combination as the House
Code DIP switches in the Solar Siren.
2. DIP Switches 1-3 of SW3 must be set as follows
for use with this alarm system:
DIP 1
DIP 2
ON
ON
3. DIP switch 4 of SW3 is used to configure the PIR
Detector for walk test mode, which allows the
operation of the detector to be checked during
installation without initiating an alarm.
ON
Walk Test mode
OFF
Normal operation
Note: On initial installation the detector should be
configured into Walk-Test mode ready for testing.
SA1/SA2/SAC1
Dip Switches
(SW2 and SW3)
PCB Position
5
Indicator
4
(positions 1-5)
3
2
1
PCB Board
(slides up and
down to adjust
position)
DIP 3
OFF
4. The PIR Detector incorporates an anti-false
alarm feature designed to compensate for
situations where the detector may be affected
by environmental changes, (e.g. insects, air
temperature, etc). This feature is called "Pulse
Count" and may be selected for 1 or 2 pulse
detection.
The recommended setting is for 1 pulse detection.
However, in cases of extreme environmental
problems or if unattributable false alarms are
experienced, it may be necessary to select 2
pulse detection.
To select the required pulse count set DIP switch
5 of SW3 as follows:
ON
1 pulse detection
OFF
2 pulse detection
Note:
The higher the Pulse Count the more
movement will be necessary before the PIR
detector will trigger the alarm.
5. Connect the PP3 Alkaline battery to the battery
clip.
Note: When the 9V Alkaline battery is connected
the LED behind the lens will rapidly flash for
approximately 2-3 minutes until the PIR has
warmed-up and stabilised.
stop flashing and turn OFF.
TESTING THE PIR MOVEMENT
DETECTORS
Ensure that the system is in service mode.
1. With the PIR detector configured in Walk Test
mode and mounted in position on the wall, allow
2-3 minutes for the detector to stabilise before
commencing the Walk test.
2. Walk into and move slowly around the protected
area, each time the detector senses movement
the LED behind the lens will flash.
Note: In normal operation, with the battery cover
on, the detector LED will not flash on movement
detection.
If necessary re-adjust the detection pattern by
adjusting the mounting position of the PCB within
the PIR housing.
The LED will then