POSITIONING THE DOOR / WINDOW
DETECTORS
The Door / Window Detector is suitable for mounting in
dry interior locations only.
Decide which doors and windows are to be protected
by fitting Door / Window Detectors, (usually the front
and back doors as a minimum will have Door / Window
Detectors fitted). However additional detectors may
be fitted where required to other more vulnerable
doors or windows, (e.g. garage, patio/conservatory
doors etc).
Ensure that the position selected for the
Door / Window Detector is within effective range of
the Control Panel.
Do not fix the Detector onto or very close to
metalwork (i.e. radiators, water pipes, etc) as this
could affect the radio range of the device.
On PVC door / window frames, it may be necessary to
space the Detector and Magnet away from the metal
surface using a plastic or wooden spacer to achieve
the necessary radio range.
INSTALLING AND CONFIGURING THE
DOOR / WINDOW DETECTORS
1.
Remove the battery cover by sliding and lifting it
off. (DO NOT use a screwdriver to lever it off).
Raised Head Screw,
Key-hole Slot Fixing
Double Sided Tape
OR Screw Fixing
TWO
Fit
Batteries
Slide Open and Lift Off
Do Not Use A Screwdriver
Small Counter-sunk
Screw Fixing
Battery
Connector
Tilt and Remove
Battery Holder
and Insert
Two Batteries
2.
Slide the two batteries supplied into the battery
holder, ensuring that the
each battery as it is installed.
3.
If necessary, refit the battery holder into the
detector ensuring that the spring clip connectors
slide onto either side of the circuit board.
The Detector should be mounted on the fixed part
of the frame and the magnet on the opening part.
The Detector and Magnet should be mounted
using the double sided adhesive pads or screws
provided.
Note: If mounting the device using the adhesive
pads, ensure that the mounting surfaces are
clean and dry before mounting.
Detector
4.
If fixing the detector with screws first remove
the battery holder by carefully tilting up the
end and pulling away from the printed circuit
board (PCB).
The top of the Detector is secured by hanging
the keyhole slot over the head of the 10mm pan
head screw. The bottom of the Detector is
secured using the 12mm counter-sunk head
screw fitted within the battery compartment.
Carefully drill out the centre of the fixing screw
hole in the battery compartment using a 3mm
drill. Fit the Magnet using the two 15mm fixing
screws. Do not over-tighten the screws as this
may distort or damage the casing.
5.
If an additional wired Magnetic Contact is
required, this should be wired to the terminal
block provided in the battery compartment.
+
side is uppermost on
Magnet
Alternative
Mountings