Note: DO NOT fix the PIR Detector to metalwork or
locate the unit within 1m of metalwork (i.e. radiators,
water pipes, etc) as this could affect the radio
range of the device.
Installing and Configuring the
PIR Movement Detector
Ensure that the system is in Service Mode
1. Undo and remove the fixing screw from the
bottom edge of the PIR Detector. Carefully pull
the bottom edge of the PIR Detector away from
the rear cover and then slide down to release
the top clips.
Mounting Hole
Positions
2. Carefully drill the required mounting holes in the
rear cover using a 3mm drill relevant to whether
the PIR Detector is being mounted in a corner or
against a flat wall.
3. Using the rear cover as a template, mark the
positions of the fixing holes on the wall.
4. Fix the rear cover to the wall using the two
18mm No.4 screws and 25mm wall plugs, (a
5mm hole will be required for the wall plugs).
Do not over-tighten the fixing screws as this
may distort or damage the cover.
Note: The wall plugs supplied with the product
are not suitable for plasterboard walls, if
mounting the PIR Detector onto plasterboard
use appropriate wall plugs.
5. Configure the PIR Detector as described in
'Setting the PIR Detectors'. Remember that on
initial installation the device needs to be tested
and should therefore be set in Walk Test Mode.
6. Check that the PIR Detector PCB is located and
set in the correct position to give the detection
zone pattern required.
7. To refit the PIR Detector to the rear cover, offer it

Setting the PIR Detector

Rear Cover
Located on the PCB of the PIR Detector are two
blocks of DIP switches (SW2 and SW3).
When setting Dip Switches to House Code, hold
the PIR Detector 'upside down' as shown in the
diagram below:
1. DIP switches SW2 (numbered 1-8) are used to
Fixing Screw
Setting for a Siren only larm System
For a Siren only larm System, DIP switches 1- 3 of
SW3 must be set as follows:
11
To adjust the PCB position, simply slide it up or
down ensuring that the location legs are aligned
with the required position number marked on
the board.
up to the rear cover and locate the clips in the top
edge into the rear cover. Push the lower edge of
the PIR Detector into place and refit the fixing
screw in the bottom edge to secure in position.
Do not over-tighten the fixing screws as this may
damage the casing.
set the House Code for the PIR Detector and
must be set to the same ON/OFF combination
as the House Code DIP switches in all other
system devices.
DIP Switches
(SW2 and SW3)
PCB Board
(slides up and
down to adjust
position)
SW2
ON
ECE
1
2
3
4
5
6
7
8
Set to House Code
Zone
Settings
DIP 1
DIP 2
ON
SW3
ON
ECE
1
2
3
4
5
Walk Test
Sensitivity
DIP 3
ON
OFF