3.18 DRAM Clear

Note: Perform a DRAM clear whenever a memory upgrade is installed to the unit or the DRAM is replaced.
1. Press <Menu>, <*>, <1>, <6>.
DRAM Clear
Yes → Enter
2. Press <Enter>. The DRAM will be cleared.
Note: To finish the operation without performing initialization, press <Cancel>.

3.19 Clear Life Monitor

The life monitor keeps a count of the pages scanned, printed, and transmitted, along with the drum
replacement count and total pages printed on the current drum. This mode clears these counters.
1. Press <Menu>, <*>, <1>, <7>.
Clear Life Monitor
Yes → Enter
2. Press <Enter>. The counters will be reset.
Note: To finish the operation without performing initialization, press <Cancel>.