Muratec F-315 Field Engineering Manual page 31

Facsimile system
Hide thumbs Also See for F-315:
Table of Contents

Advertisement

Machine Parameter 011
Initial
Switch
Setting
7
0
Adjustment of the scanning
stretching and squeezing for
6
0
ADF.
5
0
(Horizontal)
4
0
3
0
The plus setting stretches the
2
0
image data and the minus
1
0
setting squeezes it.
0
0
Each setting changes by
0.1%
Note: These values are
factory set and should not be
adjusted unless instructed by
a Muratec technical
representative.
Machine Parameter 012
Initial
Switch
Setting
7
1
Adjustment of the scanning
stretching and squeezing for
6
0
ADF.
5
0
(Vertical)
4
0
3
1
The plus setting squeezes
2
1
the image data and the minus
1
0
setting stretches it.
0
1
Each setting changes by
0.1%
Adjust
Adjust
3-5
Usage/Comments
Switch 76543210
Settings
00001111
+1.5 %
:
00001000
+0.8 %
:
00000100
+0.4 %
:
00000010
+0.2 %
00000001
+0.1 %
00000000
10000001
–0.1 %
10000010
–0.2 %
:
10000100
–0.4 %
:
10001000
–0.8 %
:
10001111
–1.5 %
Usage/Comments
Switch 76543210
Settings
00001111
+1.5 %
:
00001000
+0.8 %
:
00000001
+0.1 %
00000000
– 0.1 %
10000001
:
10000100
–0.4 %
:
10001000
–0.8 %
:
10001101
–1.3 %
:
10001111
–1.5 %
0 %
Initial setting
0 %
Standard
Initial setting