Cover Platen (Mfx-1950 Only); Cover Adf Base (F-315 Only) - Muratec F-315 Field Engineering Manual

Facsimile system
Hide thumbs Also See for F-315:
Table of Contents

Advertisement

COVER PLATEN (MFX-1950 only)

1. Remove the Cover connect. (See page 5-6)
2. Open the Cover platen.
3. Remove the Ground wire, and then raise the Cover platen.
4. Release the locking tab, and then remove the COVER PLATEN.

COVER ADF BASE (F-315 only)

1. Remove the Cover connect. (See page 5-6)
2. Open the Cover ADF base.
3. Remove the Ground wire, and then remove two Hinge mounting screws.
4. Remove the COVER ADF BASE.
Tab
Ground
wire
Platen hinge
Ground
wire
Hinge
Cover platen
Cover ADF base
5-7
5-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1950Mfx-1350F-305

Table of Contents