Machine Parameter 017
Initial
Switch
Setting
7
1
Adjustment of the scanning
stretching and squeezing for
6
0
FBS.
5
0
(Vertical)
4
0
3
0
The plus setting squeezes
2
1
the image data and the minus
1
0
setting stretches it.
0
0
Each setting changes by
0.1%
Machine Parameter 018
Initial
Switch
Setting
7
0
Leading edge document
margin adjustment For FBS
6
0
5
1
Adjusts the leading edge
4
0
margin after Home Sensor
3
1
OFF to the start of scanning
2
0
the position.
1
0
0
1
Each setting changes
by 0.0212 mm.
Note: These values are
factory set and should not be
adjusted unless instructed by
a Muratec technical
representative.
Adjust
Adjust
127steps 01111111
64 steps 01000000
41 steps 00101001
32 steps 00100000
16 steps 00010000
8 steps
– 8 steps 10001000
– 16 steps
– 32 steps
– 64 steps
– 127steps
3-8
Usage/Comments
Switch 76543210
Settings
00001111
+1.5 %
:
00001000
+0.8 %
:
00000100
+0.4 %
:
00000010
+0.2 %
00000001
+0.1 %
00000000
10000001
–0.1 %
10000010
–0.2 %
:
10000100
–0.4 %
:
10001000
–0.8 %
:
10001111
–1.5 %
Usage/Comments
Switch 76543210
Settings
+2.70 mm
:
+1.36 mm
:
+0.87 mm
:
+0.68 mm
:
+0.34 mm
:
00001000
+0.17 mm
:
00000000
21.85 mm
:
– 0.17 mm
:
10010000 – 0.34 mm
:
10100000 – 0.68mm
:
11000000 – 1.36 mm
:
11111111 – 2.70mm