3.8 T.30 Monitor
In all binary coded facsimile control procedures the HDLC frame structure is utilized. The basic HDLC
structure is shown below.
Preamble
Non-stabdard facilities frame(NSF) Called subscriber identification frame (CSI) Digital identification frame (DIS)
Flag
Flag
The control signal is identified by FCF (Facsimile Control Field). Additional 8–bit octet information follows
FIF (Facsimile Information Field) and FC (Facsimile Control Field) to further clarify facsimile procedures.
This is added to DIS, DCS, DTC, CIS, CIG, TSI, NSC, NSF, and NSS signals.

3.8.1 Print T.30 Monitor

This mode causes the unit to print a G3 procedural summary of the last fax communication.
1. From standby, press <Menu>, <*>, <0>, <5>.
2. The T.30 Monitor list will be printed.

3.8.2 Multi T.30 Monitor

The communications on the journal list are able to print.
1. Set the unique switch for Multi T.30 monitor to "1 (On)". (Unique switch 85 switch 0 )
2. Print the journal list and check the communication number of which to print the T.30 Monitor.
3. From standby, press <Menu>, <*>, <0>, <5>.
T30 Number
4. Enter the communication number and press <Enter>.
Binary coded infromation
Address
Control
3-110
Facsimili
Facsimili
contorl
information
field
field
The information in this
protion is printed in the T.30

monitor.

Frame
checing
sequence (FCS)