Muratec F-315 Field Engineering Manual page 35

Facsimile system
Hide thumbs Also See for F-315:
Table of Contents

Advertisement

Machine Parameter 019 ––– Factory use only
Machine Parameter 020
Initial
Switch
Setting
7
1
Mirror carriage standby
position adjustment
6
0
5
0
Adjusts the number of the
4
1
steps from the home sensor
3
0
of the mirror carriage OFF
2
1
to the standby position.
1
1
0
1
1 step = 0.0212 mm
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Machine Parameter 021
Initial
Switch
Setting
7
0
Mirror carriage transfer mode
position adjustment
6
0
5
0
Adjusts the number of the
4
0
steps from the home sensor
3
0
of the mirror carriage OFF
2
0
to the transfer mode position.
1
0
0
0
1 step = 0.0212 mm
Machine Parameter 022 ∼ 024 ––– Factory use only
Adjust
127steps 01111111
80 steps 01010000
50 steps 00110010
20 steps 00010100
10 steps 00001010
3 steps
2 steps
1 step
When Switch 7 is "1", it means " – ". For example,
"10000001" means "–0.14 mm".
Adjust
127steps 01111111
64 steps 01000000
32 steps 00100000
16 steps 00010000
8 steps
– 8 steps 10001000
– 16 steps
– 32 steps
– 64 steps
– 127steps
3-9
Usage/Comments
Switch 76543210
Settings
+17.89 mm
:
+11.26 mm
:
+7.04 mm
:
+2.82 mm
:
+1.41 mm
:
00000011
+0.42 mm
00000010
+0.28 mm
00000001
+0.14 mm
00000000
9.15 mm
Usage/Comments
Switch 76543210
Settings
+2.70 mm
:
+1.36 mm
:
+0.68 mm
:
+0.34 mm
:
00001000
+0.17 mm
:
00000000
21.5 mm
:
– 0.17 mm
:
10010000 – 0.34 mm
:
10100000 – 0.68mm
:
11000000 – 1.36 mm
:
11111111 – 2.70mm
Initial setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1950Mfx-1350F-305

Table of Contents