Muratec F-315 Field Engineering Manual page 87

Facsimile system
Hide thumbs Also See for F-315:
Table of Contents

Advertisement

Memory Switch 00 – Dialer
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
CED detection condition
4
0
3
0
DIS detect time after dialing
0: 55 sec
1: 70 sec
2
1
CED detection
0: No
1: Yes
1
1
Dial tone detection
0: Do not dial
1: Dial
0
0
Phone line type for the first
phone line
0: PSTN
1: PBX
Adjust
Sets whether the detection should be strict or not.
Switch
Sets the time DIS signal is detected after dialing a
number.
Can be use to ignore CED detection if noise on the
telephone line is mistaken as a 2100 Hz CED
signal.
Determines if the machine proceeds with dialing or
indicates an error if no dial tone is detected within
five seconds of going off–hook.
When set to PSTN, the machine checks for dial
tone and acts according to the setting of memory
switch 00, bit 1. When set to PBX, the machine
always dials a given number of seconds after going
off–hook. Memory switch 001 sets the number of
seconds.
3-61
Usage/Comments
Normal
350ms 500ms 700ms 1000ms
5
0
0
4
0
1
Strict
1
1
0
1

Hide quick links: