Muratec F-315 Field Engineering Manual page 54

Facsimile system
Hide thumbs Also See for F-315:
Table of Contents

Advertisement

Machine Parameter 286
Initial
Switch
Setting
7
0
Transfer current adjustment
for envelops
6
0
5
0
4
0
3
0
The plus setting increases
2
0
the current and the minus
1
0
setting decreases it.
0
0
Each setting changes by
0.11 μA.
Machine Parameter 287
Initial
Switch
Setting
7
0
Transfer current adjustment
for postcards
6
0
5
0
4
0
3
0
The plus setting increases
2
0
the current and the minus
1
0
setting decreases it.
0
0
Each setting changes by
0.11 μA.
Adjust
When transfer problems occur, adjust this
parameter.
Switch
31 steps
8 steps
–1 steps
–2 steps
–8 steps
–31 steps
When Switch 7 is "1", it means " – ". For example,
"10000001" means "–0.11 μA".
Note: Adjusting them too many steps effect the
print quality. Just try to decrease one or two steps
at first.
Adjust
When transfer problems occur, adjust this
parameter.
Switch
31 steps
8 steps
–1 steps
–2 steps
–8 steps
–31 steps
When Switch 7 is "1", it means " – ". For example,
"10000001" means "–0.11 μA".
Note: Adjusting them too many steps effect the
print quality. Just try to decrease one or two steps
at first.
3-28
Usage/Comments
76543210
Settings
+3.41 μA
00011111
:
+0.88 μA
00001000
:
0 μA
00000000
–0.11 μA
10000001
–0.22 μA
10000010
:
–0.88 μA
10001000
:
–3.41 μA
10011111
Usage/Comments
76543210
Settings
+3.41 μA
00011111
:
+0.88 μA
00001000
:
0 μA
00000000
–0.11 μA
10000001
–0.22 μA
10000010
:
–0.88 μA
10001000
:
–3.41 μA
10011111
Initial setting
Initial setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1950Mfx-1350F-305

Table of Contents