Muratec F-315 Field Engineering Manual page 283

Facsimile system
Hide thumbs Also See for F-315:
Table of Contents

Advertisement

Printer registration (side)
A
Adjust so that width A on the test pattern Checkered output falls within the following range.
Standard
10 ± 1.8 (mm)
Adjustment procedure
1. Load legal (for US version) or A4 (for European version) size paper to the cassette or tray you want to
adjust.
2. Use the Unique Switch 52 to adjust the printing margin to 0 mm. (bit 0, 1 0)
3. Printout the test pattern H: Ladder. (Press <Menu>, <*>, <0>, <9>, < >, <Enter>, < >, < >, < >,
<Enter>)
4. Check width A on the test pattern H: Ladder meets the specifications.
If width A falls outside the specified range, perform following steps to make the adjustment.
5. To use the "Printer registration mode," press <Menu>, <*>, <4>, <3> and then select the cassette.
6. Select "Vertical Regi ", and then adjust the "Vertical Registration".
If the width A is shorter than the standard, increase value.
If the width A is longer than the standard, decrease value.
7. After you have finished the adjustment, you must reenter the setting of Unique Switch 52, you
changed in step 1.
Important: The setting you have entered in Printer registration mode is reflected in the following
Machine parameters.
Cassette1 : Machine parameter 100, 140, 160
Cassette2 : Machine parameter 101, 141, 161
Bypass Tray :Machine parameter 107, 147, 167
Duplex Unit: Machine parameter 108, 148, 168
Adjustment Tool
Machine parameter: 100, 140, 160
5-71
5-71
A
Test pattern H
Setting Range
–12.8 to 12.7 (mm)
(0.6773 mm step)