Object Left / Removed - Dedicated Micros SD Excel Installation Manual

Hide thumbs Also See for SD Excel:
Table of Contents

Advertisement

Object Left / Removed

Object Left / Removed is used to define specific areas of the camera view where an alert can be
generated if an object is detected as being removed or added.
An AnalyticsCapable license enables this feature for all connected analogue cameras.
On a single camera, up to 16 regions of the camera view can be specified to be monitored for object changes.
Camera Options will configure settings for the camera. Region Options effect only the region (detection
area) currently being configured.
To size and position the detection area, use the mouse to click, drag and release the white selection
points in the corners of the detection area.
Camera Options
Noise Tolerance
This sets the background 'noise' level which the camera will ignore.
Setting the noise tolerance level too low could result in a false alarm.
Dedicated Micros recommend that a well maintained camera viewing
an adequately illuminated scene should be
set at '8'.