Specifications - IBM 265 Service Manual

Table of Contents

Advertisement

Specifications

Dimensions
Height
Width
Depth
Weight
Minimum configuration
Maximum configuration
Electrical
Power source loading
(maximum in kVA)
Power source loading (typical in
kVA)
Voltage range (V ac)
Frequency (hertz)
Voltage range (V dc)
Thermal output (maximum)
Thermal output (typical)
Power requirements (maximum)
Power requirements (typical)
Power factor - US, World Trade,
Japan
Inrush current²
Maximum altitude³,
Temperature Requirements³
Humidity Requirements
(Noncondensing)
Wet Bulb
Noise Emissions¹,
L
WAd
<L
>
pA
m
Install/Air Flow
1. Inrush currents occur only at initial application of power, no inrush occurs during normal
power off-on cycle.
2. The upper limit of the dry bulb temperature must be derated 1 degree C per 137 m (450 ft.)
above 915 m (3000 ft.).
3. The upper limit of the wet bulb temperature must be derated 1 degree C per 274 m (900 ft. )
above 305 m (1000 ft.).
4. Levels are for a single system installed in a T00 32 EIA rack with the center of the unit
approximately 1500 mm (59 in.) off the floor.
20
Service Guide
426 mm (16.8 in.)
215 mm (8.5 in..
617 mm (24 in.).
35.5 kg 78 lbs.
43.1 kg 94.8 lbs.
100 to 127 or 200 to 240 (autoranging)
Not supported
1536 Btu/hr
1024 Btu/hr
450 watts
300 watts
70 amps
2135 m (7000 ft.)
Operating
10 to 40°C
(50 to 104°F)
Operating
8 to 80%
27°C (80°F)
Operating
6.1 bels
42 dBA
Maintenance of proper service clearance should allow proper
air flow.
0.46
0.31
50 / 60
0.98
Non-Operating
10 to 52°C
(50 to 126°F)
Non-Operating
8 to 80%
27°C (80°F)
Idle
6.1 bels
41 dBA