Table 3. Firmware Error Codes. (continued)
Error Code Description
40110004 Low voltage detected in power supply
main enclosure.
40110005 Fan warning detected in power supply
main enclosure.
40110006 Fan failure detected in power supply main
enclosure.
40110007 Thermal warning detected in power
supply main enclosure.
Action / Possible Failing FRU
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. If a location code is displayed with
this error code, replace the part at
that location.
3. Look at the service processor error
log for more error information.
4. Reseat the power supplies
5. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
Chapter 5. Error Code to FRU Index
137