Table 3. Firmware Error Codes. (continued)
Error Code Description
40112063 Critically low 1.8 V reading detected
40112064 Critically high 1.8 V reading detected
40112065 Critically low 2.5 V reading detected
40112066 Critically high 2.5 V reading detected
148
Service Guide
Action / Possible Failing FRU
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the processor cards.
Location: P1-C1
Location: P1-C2
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the processor cards.
Location: P1-C1
Location: P1-C2
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the processor cards.
Location: P1-C1
Location: P1-C2
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the processor cards.
Location: P1-C1
Location: P1-C2