Table 3. Firmware Error Codes. (continued)
Error Code Description
2BA00303 Service processor reports slow fan
2BA00309 Service processor reports generic cooling
2BA00310 Service processor reports processor card
2BA00311 Service processor reports system board
2BA00312 Service processor reports memory over
2BA00313 Service processor reports generic power
2BA00314 Service processor reports 5 V over
130
Service Guide
number 4.
alert.
over temperature alert.
over temperature alert.
temperature alert.
alert.
voltage alert.
Action / Possible Failing FRU
1. Replace fan 4.
Location: F4
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Check for cool-airflow obstructions
to the system.
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Check for cool-airflow obstructions
to the system.
2. If the problem persists, replace
processor card.
Location: P1-C1
Location: P1-C2
1. Check for cool-airflow obstructions
to the system.
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Check for cool-airflow obstructions
to the system.
2. Replace the memory card.
Location: P1-M1
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 109.)