Table 3. Firmware Error Codes. (continued)
Error Code Description
40110008 Thermal failure detected in power supply
40110009 Overvoltage detected on 5 volt line in
4011000A Overvoltage detected on 5 volt line in
4011000B Overvoltage detected on 5 volt line in
138
Service Guide
main enclosure.
power supply main enclosure
power supply main enclosure
power supply main enclosure
Action / Possible Failing FRU
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3