IBM 265 Service Manual page 150

Table of Contents

Advertisement

Table 3. Firmware Error Codes. (continued)
Error Code Description
2BA00351 Service processor reports generic AC
2BA00352 Service processor reports loss of AC
2BA00353 Service processor reports loss of AC
2BA00356 Service processor reports fan failure in a
2BA00357 Service processor reports
2BA00358 Service processor reports redundant
2BA00399 Service processor reports unsupported
134
Service Guide
power loss EPOW.
power (outlet).
power (power button).
power supply
over-temperature condition in a power
supply
power supply failure
value in EPOW.
Action / Possible Failing FRU
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3.
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3.
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3.
1. Check EPOW cabling on SCSI or
SSA backplanes.
2. Replace the system board.
Location: P1
(See note 3 on page 109.)