Bus Srn To Fru Reference Table - IBM 265 Service Manual

Table of Contents

Advertisement

Bus SRN to FRU Reference Table

This table is used to locate defective FRUs within the system board PCI and ISA buses.
The table indicates which devices should be tested for each SRN. For this procedure, if
possible, diagnostics are run on the system board bus devices with all adapters
removed from the failing bus. If a failure is detected on this system with all adapters
removed from the failing bus, the system board is the isolated FRU. If a failure is not
detected, the adapters are added back one at a time, to their original slot location, and
the configuration is tested until a failure is detected. The failure is then isolated to the
failing FRU.
If a failure has not been detected and all the FRUs have been tested, call technical
service support for assistance.
Table 5. Bus SRN to FRU Reference Table
SRN
9CC-100
9CC-101
651-730
Bus
Possible Failing Device and AIX
Identification
Location Code
PCI Bus 00
Internal SCSI port (10-60)
Internal/external SCSI port (10-61)
Internal Ethernet port (10-80)
Device installed in I/O slot 3 (10-68
to 10-6F)
Device installed in I/O slot 4 (10-70
to 10-77)
Device installed in I/O slot 5 (10-78
to 10-7F)
PCI Bus 40
Device installed in I/O slot 1 (20-58
to 20-5F)
Device installed in I/O slot 2 (20-60
to 20-67)
ISA Bus
Diskette drive port/device
(01-D1-00-00)
Parallel port/device (01-R1)
Serial ports (1, 2, 3)/device (01-S1,
01-S2, 01-S3)
Mouse port/device (01-K1-01-00)
Keyboard port/device (01-K1-00-00)
Associated FRU
System board.
(See notes on
page 109.)
System board.
(See notes on
page 109.)
System board.
(See notes on
page 109.)
Adapter
Adapter
Adapter
Adapter
Adapter
System board.
(See notes on
page 109.)
System board.
(See notes on
page 109.)
System board.
(See notes on
page 109.)
System board.
(See notes on
page 109.)
System board.
(See notes on
page 109.)
Chapter 5. Error Code to FRU Index