Bus Srn To Fru Reference Table - IBM RS/6000 7043 43P Series Service Manual

Hide thumbs Also See for RS/6000 7043 43P Series:
Table of Contents

Advertisement

Table 4-1 (Page 11 of 11). Firmware Error Codes
Error Code
Function /
Description
28A00040
Fan failure
28A00050
Power Supply
Failure
Keyboard/Mouse problems
29000002
Keyboard/Mouse
controller failed
selftest
29A00003
Keyboard not
present/detected
29A00004
Keyboard stuck key
detected
29B00004
Mouse not
present/detected

Bus SRN to FRU Reference Table

This table is used to locate defective FRUs within the I/O board PCI and ISA buses.
The table indicates which devices should be tested for each SRN. For this
procedure, if possible, diagnostics are run on the I/O board bus devices with all
adapters removed from the failing bus. If a failure is detected on this system with all
adapters removed from the failing bus, the I/O board is the isolated FRU. If a failure
is not detected, the adapters are added back one at a time, to their original slot
location, and the configuration is tested until a failure is detected. The failure is then
isolated to the failing FRU.
If a failure has not been detected and all the FRUs have been tested call your
technical service support person for assistance.
Repair Action/Possible Failing FRU
Check on the following:
Ensure fans are properly connected to the I/O
planar
Reseat all suspected fan(s) connectors
Look for obstructions that may prevent the fans
from normal operations. (For example, a cable
caught in the fan preventing it from spinning.)
Replace any suspected fan(s) that may cause this
error
If after replacing the suspected fan(s) and the
problem still exists, then replace the system board.
Replace the power suppply
1. Replace System Planar
1. Keyboard
2. Replace System Planar
1. Keyboard
2. Replace the System Planar.
1. Mouse
2. Replace System Planar
Chapter 4. Error Code to FRU Index for the Model 150
4-11