Configuring Advanced IPSec/IKE Parameters

After you have pre-configured IPSec via SSH (refer to ''Securing EMS-Device
Communication'' on page 196), you can optionally configure additional IPSec and IKE
entries for other SNMP Managers aside from the EMS.
Note:
To configure IPSec/IKE tables:
1.
In the MG Tree, select the device.
2.
On the Tab bar, select General Configuration, and then click Info & Security; the
'MG Info and Security Provisioning' screen is displayed.
3.
Select the IPSec Table tab; the 'IPSec Table' screen is displayed.
4.
Select the
a row is added to the table.
5.
Double-click each field to insert required values.
6.
Right-click the new entry, and then from the shortcut menu, choose Unlock rows.
7.
Click Save, and then Close.
8.
Select the IKE Table tab; the 'IKE Table' screen appears.
9.
Repeat steps 4 through 7.
SIP User's Manual
Do not remove the default IPSec and IKE tables that were previously loaded
to the device when you enabled IPSec.