AudioCodes MP-124 User Manual page 376

Cpe & access analog gateways
Hide thumbs Also See for MP-124:
Table of Contents

Advertisement

An example of a User Information file is shown in the figure below:
Note:
The User Information file can be loaded to the device by using one of the following
methods:
ini file, using the parameter UserInfoFileName (described in ''Auxiliary / Configuration
Files Parameters'' on page 360)
Web interface (refer to ''Loading Auxiliary Files'' on page 168)
Automatic update mechanism, using the parameter UserInfoFileURL (refer to the
Product Reference Manual)
Each PBX extension registers separately (a REGISTER message is sent for each entry
only if AuthenticationMode is set to Per Endpoint) using the IP number in the From / To
headers. The REGISTER messages are sent gradually. Initially, the device sends requests
according to the maximum number of allowed SIP dialogs (configured by the parameter
NumberOfActiveDialogs). After each received response, the subsequent request is sent.
Therefore, no more than NumberOfActiveDialogs dialogs are active simultaneously. The
user name and password are used for SIP Authentication when required.
The calling number of outgoing Tel-to-IP calls is first translated to an IP number and then (if
defined), the manipulation rules are performed. The Display Name is used in the From
header in addition to the IP number. The called number of incoming IP-to-Tel calls is
translated to a PBX extension only after manipulation rules (if defined) are performed.
SIP User's Manual
Figure 8-1: Example of a User Information File
The last line in the User Information file must end with a carriage return (i.e.,
by pressing the <Enter> key).
376
MP-11x & MP-124
Document #: LTRT-65412

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents