SIP User's Manual
Parameter
Web: Broken Connection Timeout
EMS: Broken Connection Event
Timeout
[BrokenConnectionEventTimeout]
Web: Disconnect Call on Silence
Detection
EMS: Disconnect On Detection Of
Silence
[EnableSilenceDisconnect]
Web: Silence Detection Period [sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeriod]
Silence Detection Method
[FarEndDisconnectSilenceMethod]
[FarEndDisconnectSilenceThreshold]
Version 5.8
6. Configuration Parameters Reference
The time period (in 100 msec units) after which a call is
disconnected if an RTP packet is not received.
The valid range is 1 to 1,000. The default value is 100
(i.e., 10 seconds).
Notes:
Applicable only if DisconnectOnBrokenConnection is
set to 1.
Currently, this feature works only if Silence
Suppression is disabled.
Determines whether calls are disconnected after detection
of silence.
[1] Yes = The device disconnects calls in which silence
occurs (in both call directions) for more than a user-
defined time.
[0] No = Call is not disconnected when silence is
detected (default).
The silence duration can be set by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note: To activate this feature, set
EnableSilenceCompression and
FarEndDisconnectSilenceMethod to 1.
Duration of the silence period (in seconds) after which the
call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is
120 seconds.
Note: For this parameter to take effect, a device reset is
required.
Silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
[2] Voice/Energy Detectors = According to energy and
voice detectors (default).
[3] All = According to packet count, and energy and
voice detectors.
Note: For this parameter to take effect, a device reset is
required.
Threshold of the packet count (in percentages) below
which is considered silence by the device.
The valid range is 1 to 100%. The default is 8%.
Notes:
Applicable only if silence is detected according to
packet count (FarEndDisconnectSilenceMethod is set
to 1).
For this parameter to take effect, a device reset is
required.