11,100.60 Electronics Module Temperature Fault

The root problem for this error is temperature sensitivity with the power supply's opto-isolator
chips. The following troubleshooting procedure applies to this error:
Program Faults
11,100.60
The system reports an overheat condition.
Initial Actions
Check the ambient room temperature.
Check for obstructions in the Air Vents. If obstructions are cleared, allow time for the sys-
tem to cool.
If the problem persists, follow the procedure below.
Primary Causes
The troubleshooting table lists parts and wiring referenced in the troubleshooting procedure.
Table 1 11,100.60 Troubleshooting Reference Table
Applicable Parts
Wiring and Plug/Jack References
Electronics Module,
PL 5.0
Electronics Module Power -
Electronics Module Fan,
PL 4.0
Left Side Harness (2/2) -
Troubleshooting Procedure
Table 2 Temperature Fault 11,100.60 Troubleshooting Procedure
Step Questions or Actions
1
Check that the air ducts are free of
obstructions and the fans are operating
correctly.
Are the fans operating correctly?
Initial Issue
Phaser 8860/8860MFP Service Manual
Figure 9
Figure 7
Yes
No
Replace the Elec-
Replace the defec-
tronics Module
(REP
tive fan.
5.0.5).

11,300.6x EMC Motor Control Faults

A software error has occurred. The following troubleshooting procedure applies to these errors:
Program Faults
11,300.6x
Motor told to move too late..
Initial Actions
Reset NVRAM and retest.
If the problem persists, follow the procedure below.
Primary Causes
The troubleshooting table lists parts and wiring referenced in the troubleshooting procedure.
Table 1 11,300.6x Troubleshooting Reference Table
Applicable Parts
Wiring and Plug/Jack References
Electronics Module,
PL 5.0
Electronics Module Power -
Troubleshooting Procedure
Table 2 12,000.60 Program Faults Troubleshooting Procedure
Step Questions or Actions
1
Reseat all Electronics Module connec-
tions.
Does the problem persist?
2
Check ground integrity.
Are the system grounds connected?
09/2007
2-25
Figure 9
Yes
No
Go to Step 2.
Complete.
Replace the Elec-
Reconnect the sys-
tronics Module
(REP
tem grounds.
5.0.5).
Error Messages and Codes
11,100.60, 11,300.6x