Table 1 Test Selection Numbers
No. Test Name
No. Test Name
33
Paper Lead Edge Times
77 Clear PE NVRAM
34 Paper Trail Edge Times
78 Set PE NVRAM To
Defaults
35 Paper Sensor Bounce
79 Print DMU Blot
Times
36
Duplex Paper Drive Power 80 Display Fault History
37
Duplex Paper Lead Edge
81 Monitor Sensors
Times
38 Duplex Paper Trail Edge
82 Monitor Encoders
Times
39 Duplex Paper Sensor
83 Monitor Temperatures
Bounce Times
40 Clear Paper Path Data
84 Monitor Heaters
41
Wiper Drive
85 Monitor Line Voltage
42
Paper Path Drive
86 Report MFP Configura-
tion
43 X-axis Drive
87 Report EM FW Version
From System Off Directly to Diagnostic Mode:
When the system powers up in Diagnostic mode, the current Printhead temperature is mea-
sured. If Printhead reservoir temperature is greater than 110 degrees, thermal regulation is
restarted to keep the system warm while diagnostic tests are being run. This thermal regulation
is in addition to any test-specific initialization requirements. If possible, each test attempts to
leave the system warm. If a failure is encountered, the heaters may be turned off. If the initial
temperature is cold, thermal regulation is not started.
1.
Turn the system power On and wait for the Xerox logo to begin moving across the display
2.
Before the logo is centered on the display (stops moving), press and hold the Back and ?
buttons on the Control Panel.
3.
Hold both buttons until the display reads "Beginning Service Mode Initialization". Release
the buttons and the system reboots into service mode with the Service Diagnostics menu
displayed.
Initial Issue
Phaser 8860/8860MFP Service Manual
Service Diagnostics Menu
When the system is powered up (or reset) directly into Diagnostic mode, or Enter Diagnostics
No. Test Name
is selected from the Hidden Service menu, the initial Control Panel displays the Service Diag-
121 Test FAX Modem Sub-
nostics menu. The display reverts back to this menu whenever a test terminates. On return, the
system
highlighted menu item is the previously selected test. Use the Control Panel buttons as
122 Reset FAX Subsystem
described in
123 Report FP FW Version
Button
124 Monitor FP Buttons
BACK
125 Exercise FP Display
126 Exercise FP LEDs
CANCEL
127 Initialize Mechanism
?
UP
DOWN
ENTER
NOTE: Pressing any key may cause an abort if allowed by the test being performed. A power
cycle is used to arbitrarily stop a test.
09/2007
6-7
Table 2
to navigate the menu, select tests and respond to prompts.
Table 2 Control Panel Button Functions in Service Diagnostics
Function
Returns to the prior higher level menu structure, if available.
Cancels the display of test results on the control panel and allows the current
test to complete. If help text is displayed on the control panel, pressing BACK
restores the current menu item and removes the help text.
Cancels certain functions of the system
Provides help information about the current menu selection, if available.
Press any key to advance through the help text.
Scrolls up one menu item within a menu list. This control does not 'wrap'.
Used to increment data in tests requiring user input.
Scrolls down one menu item within test results. This control does not 'wrap'.
Used to decrement data in tests requiring user input.
Enters the highlighted menu. Executes the current test item.
Diagnostics
Service Diagnostics