ACCOUNT
NUMBER
#
Partition n
1 -6
#
Acct. Number
00000
Concord 4 Series Systems
Exiting Programming Mode
After all installer/dealer programming is completed, use the following procedure to exit program-
ming mode.
To exit programming mode:
1.
Press * until the display shows
2.
Press A or B until the display shows
3.
Press # and the touchpad displays the
Entering Quick Programming Mode
The Quick Programming Mode allows basic system programming using a SuperBus 2000 Fixed
Display Touchpad or any SuperBus 2000 Alphanumeric Touchpad. The following menus are
accessible:
•
Account Number (all partitions)
•
CS Phone 1
•
CS Phone 2
•
CS Phone 3
•
Learn Sensors—limited to selecting sensor number, sensor group, and partition assignment.
An alphanumeric touchpad is required for programming sensor text in standard program-
ming mode.
To enter Quick Programming Mode:
1.
Make sure the system is disarmed in all partitions.
2.
Press 8 + installer/dealer CODE + 03. The display shows
3.
Cycle through the menus as shown below:
B
CS PHONE
A
#
#
CS Phone 1
CS Phone 2
B
A
#
#
CS Phone
CS Phone
None
None
Entering User Programming Mode
The user programming mode lets you view system version information and program the follow-
ing system settings:
•
Time and Date
•
User Codes
•
Options
•
Set Up Schedules
•
Attach Schedules to Events
•
Energy Saver
•
Attach Lights to Sensors
•
System Version
You can enter user programming from an alphanumeric or fixed display touchpad by using the
system or partition master code. The default system master code is 1234.
To enter user-programming mode:
Press 9 + CODE. The display shows
WWW.DIYALARMFORUM.COM
.
SYSTEM PROGRAMMING
EXIT PROGRAMMING READY
.
TIME AND DATE
B
SENSOR
A
#
#
CS Phone 3
Sensor Partition n
B
A
#
#
CS Phone
Sensor Group
None
#
Trip Sensor n
.
TIME AND DATE
.
.
ACCOUNT NUMBER
B
LEARN
END PRO-
GRAMMING
A
1 -6
0
1-96
#
62