Option 44: Not Available

Option 45: CPC Enable

When CPC Enable is set to ON, the panel automatically detects a remote
phone hang-up and disconnects the phone line.
Note
Your local telephone company can determine if the CPC Enable option operates
with their existing equipment.

Option 46: Alarm Clear

When Alarm Clear is set to ON, alarms are cleared from panel memory and
no reports are sent after a two-way session ends; also, the Status button
stops flashing. If a two-way session does not occur and Cancel has been
pressed, a Cancel Report is sent to the central monitoring station.
When the option is set to OFF, the Status button flashes and an alarm
remains in panel memory until Status is pressed.
Note
For ETL listed systems, the Alarm Clear option must be set to OFF.
Option 47 – 50: Not Available

Option 51: Open / Close Report

When Option 51 is set to ON, the panel contacts the central station, pager,
or voice event notification each time the Power button is pressed.
In order for the Open/Close Report option to function, either Option 40 or
Option 41 must be set to ON. In addition to sending a report, each time your
customer presses Power, the panel announces that medication reminders
and/or activity checks are set to on or off.
19

Exiting Program Mode

¾
To exit Program Mode and save changes:
1. Close panel cover.
Š If you close the panel cover while in Program Mode, each programmed change is saved. If
you want to continue programming, open the panel cover and enter your Access Code.
Š When the panel cover is closed, the panel returns to Operating Mode.
Note
After you have closed the panel cover, wait approximately five seconds before setting the power switch
to OFF. This gives the system enough time to save each programmed change.

Resetting Panel Programs to Default

¾
To reset Panel Programs to default:
1. On the panel back, set the Power switch to OFF.
2. Open the panel cover.
3. Using the Installer Template, simultaneously press Done, 0, and Test. Next, set the switch on
the panel's back to ON. Continue pressing the buttons until the panel announces "Hello, sys-
tem X is OK."
4. Release the buttons.
Note
If Communication Lock (Option 8) is set to ON, the following options cannot be reset to their respective
default setting: Options 3, 4, 6-11, Utility Master Code 1 and Access Codes 1–5.
After resetting panel programs to default, you must also reset the panel clock.
Range =On/Off (Default = On)
¾
To program CPC Enable:
1. Press Add or Delete.
2. Press Option #.
3. Press 4, then 5.
4. Press Done.
Range = On/Off (Default = On)
¾
To program Alarm Clear:
1. Press Add or Delete.
2. Press Option #.
3. Press 4, then 6.
4. Press Done.
Range = On/Off (Default = Off)
¾
To program Open/Close Report:
1. Press Add or Delete.
2. Press Option #.
3. Press 5, then 1.
4. Press Done.
Programming Options