About This
Manual
1
This manual provides information for planning, installing, programming, and testing this security
system. When necessary, this manual refers you to other documentation included with compati-
ble peripherals.
Planning sheets are included for you to record hardware layout and software programming set-
tings.

About the User's Guide

The User's Guide (466-2183) contains user worksheets that should be filled out during the instal-
lation and programming of the system. For multi-partition systems, a User's Manual for each
partition is suggested.

Special Installation Requirements

This security system can be used as a fire warning system, an intrusion alarm system, an emer-
gency notification system, or any combination of the three.
Some installations may require configurations dictated by city/state codes, insurance, or Under-
writer's Laboratories (UL). This section describes the various component and configuration list-
ings.

UL Listed Installations

This section describes the requirements for UL Listed installations.

Basic System

Control Panel (600-1021-95R Concord 4 RF, 600-1022-95R Concord Express V4, 600-1040
Concord Commercial V4, or 600-1042 Concord 4 Hybrid)
Standard Class II 16.5 VAC, 40 VA power transformer 22-145 (order #600-1023) or 22-
145-CN (order #600-1023-CN), or Power Line Carrier Class II 16.5 VAC, 40 VA power
transformer 22-149 (order #600-1024) or 22-149-CN (order #600-1024-CN). These trans-
formers must be ordered separately from GE Security.
Backup Battery 12V 4.5 Ah (60-681) or 12V 7 AH (60-680)
®
SuperBus
2000 Fixed Display Touchpad (60-820), 2x16 LCD Touchpad (60-746-01),
ATP1000 (60-983) ATP2100 (60-985), ATP 2600 (60-984), 2x20 LCD Touchpad (60-803),
or 2x20 VFD Touchpad (60-804)
Interior Speaker Siren (60-528), Hardwire Interior Siren (13-949), or Speaker Siren (13-060)
Basic system may also include a SuperBus 2000 RF Receiver (60-764-95R-01) or a SuperBus
Transceiver (600-1025-01-95R).

Household Burglary Alarm System Unit (UL 1023)

Basic system, plus:
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/Window Sen-
sor (60-362)
Immediate Beeps set to on
UL 98 Options set to on
Receiver Failure set to on (if wireless devices are used)
Siren Verify set to on
Exit Delay set to 60 seconds
Quick Exit set to off
Siren Timeout set to 4 minutes or more
Entry Delay set to 45 seconds or less
RF TX Timeout set to 24 hours (if system includes a built in receiver or SuperBus 2000 RF
Receiver or SuperBus 2000 RF Transceiver and wireless burglary sensors)
Extended Delay set to off
Sleep Time set to off
Two Trip Error set to off
Alarm Verify set to off
Disable Trouble Beeps set to off