Cancel Message (02007); Call Wait Cancel (02009) - GE Concord 4 Series Installation Instructions Manual

Security systems
Hide thumbs Also See for Concord 4 Series:
Table of Contents

Advertisement

Cancel Message (02007)

This setting determines whether or not the panel displays a cancel mes-
sage after the user disarms the system to clear an alarm condition.
Pager Delay (02008)
This setting determines how long a report is delayed to a pager, after the
panel dials the pager number.
Note
The Pager Delay time should not be set below 5 seconds, unless absolutely
necessary.

Call Wait Cancel (02009)

This feature lets you set up a dialing prefix to disable the call waiting
feature before the panel makes its first dialing attempt to any pro-
grammed central monitoring station or downloader phone number. The
prefix can be up to eight digits.
To enter pauses, press C.
To enter *, press and hold 7 for one second.
To enter #, press and hold 9 for one second.
Note
It is recommended that you program two pauses in any Call Wait Cancel dial-
ing prefix to help ensure successful operation of this feature.
DO NOT change this option from its default until verifying with
!
the customer that they have call waiting with their phone service
provider. Changing this option from its default without call waiting
will prohibit the panel from calling the central station.
Caution
Dial Tone Detect (02010)
When this setting is on, the panel begins dialing as soon as it detects a
dial tone. When this feature is off, the panel begins dialing a few sec-
onds after seizing the phone line.
Note
There is no Dial Tone Detect on the last dialing attempt.
37
The following sections describe the Phone Options settings that appear under
A Phone Interface/Voice Module must be installed for the system to use the settings under
PHONE OPTIONS— PARTITION 1-6 (except Line Fail Delay)
WWW.DIYALARMFORUM.COM
Phone Options-Global (Default = on)
To turn Cancel Message off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Phone Options-Global (Default = 15 sec.)
To set the Pager Delay time:
1.
With the display showing
(current setting), enter a delay time (0–
SECS
30). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Phone Options-Global (Default = none)
To set up Call Wait Cancel:
1.
With the display showing
(or current setting), enter the desired prefix.
__
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
To delete the Call Wait Cancel prefix:
1.
With the display showing
(or current setting), press D.
__
Phone Options-Global (Default = on)
To set up Dial Tone Detect:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
.
Concord 4 Series Systems
CANCEL MESSAGE
PAGER DELAY nn
CALL WAIT CANCEL
CALL WAIT CANCEL
DIAL TONE DETECT
.
PARTITION 1-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

600-1021-95r600-1022-95r600-1040600-1042

Table of Contents