Backup (cs phone 1: 01005, cs phone 2: 01015,
cs phone 3: 01025)
This setting determines whether or not the panel uses another programmed
central station phone number for reporting if attempts with the first num-
ber are unsuccessful.
When Back Up is off, the panel will make up to eight attempts to deliver a
report with the programmed phone number.
When Back Up is set to on, the panel makes up to 16 attempts to deliver
the report, alternating between the programmed phone number and the
backup phone number.
CS PHONE 1 is backed up by CS PHONE 2.
CS PHONE 2 is backed up by CS PHONE 1.
CS PHONE 3 is backed up by CS PHONE 1.
SIA/CID Reporting (cs phone 1: 01006,
cs phone 2: 01016, cs phone 3: 01026)
This setting determines whether the panel uses the SIA or CID (Contact
ID) reporting format for central station communication.
Cellular Backup (cs phone 1: 01007, cs phone 2: 01017,
cs phone 3: 01027)
This setting determines whether the panel uses cellular communication
for reporting if attempts using a landline are unsuccessful.
Phone Number (pager 1: 01030, pager 2: 01040, pager 3:
01050, pager 4: 01060, pager 5: 01070)
This setting is used for programming a phone number that communicates
to a pager. Phone numbers can be 1 to 24 digits long and include pauses,
a skylink number, and 7-digit PIN number.
Note
Call-waiting services should be disabled to prevent interrupting panel commu-
nication to the pager(s). To program a dialing prefix that disables call-waiting,
see the Call Wait Cancel setting under the menu
BAL
.
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
33
The following describes how to program the Phones settings that appear under
.
5
PHONE OPTIONS—GLO-
WWW.DIYALARMFORUM.COM
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
To turn Backup off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Phones-CS 1-3 (Default = CID)
To select SIA or CID reporting:
1.
With the display showing
(current setting), press 1 (for SIA) or 2
SIA/CID
(for CID). The display flashes the entered set-
ting.
2.
Press # and the display shows the new setting.
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
To turn Cellular Backup off or on:
1.
With the display showing
press 1 (off) or 2 (on). The display flashes the
entered setting.
2.
Press # and the display shows the new setting.
Phones-Pager Phone 1-5 (Default = none)
To program a Pager Phone Number:
1.
With the display showing
(or current number), enter the desired pager
phone number. The display flashes the entered
number.
2.
Press # and the display shows the new setting.
To delete a Pager Phone Number:
1.
With the display showing
(current number), press D. The display shows
.
PHONE NUMBER _
Concord 4 Series Systems
BACK UP OFF/ON
REPORTING FORMAT
,
CELLULAR BACKUP
PAGER PHONE 1-
PHONE NUMBER _
PHONE NUMBER