Quick Arm (0011 - 0061)
Quick Arm allows system arming without using an access code. When
Quick Arm is on, the system arming level can be increased from Level 1-
OFF to LEVEL 2-STAY, from Level 1-OFF to LEVEL 3-AWAY, or from
Level 2-STAY to LEVEL 3-AWAY, without entering an access code.
A valid access code is still required to decrease the arming level or disarm
the system.
Quick Exit (0012 - 0062)
This setting determines whether or not users can open and close a standard entry/exit
door without causing an alarm (while the system is armed).
This feature would be useful if the user wants to go out to get the morning paper
while the system is armed. This feature also allows the user to leave the armed pre-
mises without having to disarm and re-arm the system.
When Quick Exit is on, pressing D on a touchpad (while the system is armed) starts a
2-minute timer that allows one standard entry/exit door (sensor groups 10 and 19
only) to be activated once (opened, then closed).
When this feature is turned off, the system must be disarmed before any protected
door is opened.
Note
For UL Listed installations, this feature must be set to off.

Exit Extension (0013 - 0063)

This setting determines whether or not the user can re-enter and exit again through an
entry or exit delay door (without disarming and re-arming the system). This helps
prevent exit faults and false alarms by allowing users to re-enter the premises for a
forgotten item.
When Exit Extension is on, the panel restarts the exit delay timer if the user re-enters
the premises through a standard delay door before the standard exit delay time
expires.
When this feature is off, the exit delay timer does not restart if the user re-enters the
premises, forcing the user to disarm the system to avoid setting off an accidental
alarm.
Keyswitch Sensor (0014 - 0064)
This feature lets users arm and disarm the system using either a keyswitch wired
to a hardwire zone input or a wireless door/window sensor.
Note
It is recommended that keyswitch sensors are learned into group 28.
For example, if sensor 1 is designated as the keyswitch sensor and the system is
disarmed, then tripping sensor 1 could arm the system to AWAY. If the system
is armed to STAY or AWAY, then tripping the sensor could disarm the system
(depending on keyswitch style).
The panel reports opening, closing, and force armed reports (if turned on) to the
central monitoring station.
Note
A bypassed keyswitch sensor cannot arm or disarm the system.During an audible
alarm, keyswitch sensors can disarm the system (which sends a cancel report to the
central monitoring station), but cannot arm the system. The system can be armed only
after the siren timeout expires.Keyswitch sensors test the same as any other sensor
and do not arm or disarm the system during a sensor test.
Concord 4 Series Systems
WWW.DIYALARMFORUM.COM
Security-Partition 1-6 (Default = off)
To turn Quick Arm off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on).
ON
The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Security-Partition 1-6 (Default = on)
To turn Quick Exit off or on:
1.
With the display showing
(current setting),
EXIT OFF/ON
press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the
new setting.
Security-Partition 1-6 (Default = on)
To turn Exit Extension off or on:
1.
With the display showing
EXTENSION OFF/ON
ting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2.
Press # and the display shows the
new setting.
Security-Partition 1-6 (Default = none)
To assign a Keyswitch Sensor:
1.
With the display showing
(current sensor number),
SENSOR nn
enter the desired sensor number (01–
96). The display flashes the entered
sensor number.
2.
Press # and the display shows the new
number.
To delete a Keyswitch Sensor:
1.
With the display showing
(current sensor number),
SENSOR nn
press D to erase the keyswitch sensor
attribute.
QUICK ARM OFF/
QUICK
EXIT
(current set-
KEYSWITCH
KEYSWITCH
30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

600-1021-95r600-1022-95r600-1040600-1042