Alarm Verify (06108 - 06608) - GE Concord 4 Series Installation Instructions Manual

Security systems
Hide thumbs Also See for Concord 4 Series:
Table of Contents

Advertisement

Latchkey Format (06105 - 06605)
(Default = off) This setting determines whether the selected partition is set up for
basic (off) or advanced (on) latchkey opening report operation.
Basic:
If the partition is armed by entering 2 (or 3 ) + CODE, disarming using a desig-
nated latchkey user code or keychain touchpad within an assigned time schedule
sends a page.
Arming the partition by entering 2 (or 3 ) + CODE + 6 (Latchkey) sends a page.
If the partition is armed by entering 2 (or 3 ) + CODE + 6 (Latchkey), disarming
using a designated latchkey user code or keychain touchpad inside or outside of
an assigned time schedule sends a page.
Advanced:
Arming the partition by entering 2 (or 3 ) + CODE + 6 (Latchkey) within an
assigned time schedule sends a page.
If the partition is armed by entering 2 (or 3 ) + CODE + 6 (Latchkey), disarming
using a latchkey designated user code or keychain touchpad within an assigned
time schedule sends a page.
Refer to the User's Guide for complete Latchkey setup and operation.
Freeze Alarm (06106 - 06606)
This setting determines whether the panel reports a freeze alarm to the
central station or pager, when the selected partition's energy saver
module detects a temperature that matches a predetermined setting (see
BUS DEVICES—UNIT ID—ENERGY OPTIONS—FREEZE TEMP, or
).
FREEZE TEMP below
Freeze Temp (06107 - 06607)
This setting determines the temperature point the Energy Saver Module
detects a potential freeze (heating failure) condition. The adjustable
°
°
range is from 40
- 90
F.
Note
This is the same menu found under ACCESSORY MODULES/BUS
DEVICES/UNIT ID/ENERGY OPTIONS.

Alarm Verify (06108 - 06608)

This setting determines whether the panel reports to the central moni-
toring station after a single sensor or zone trip (off) or waits for a sec-
ond trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If Alarm
Verify is set to on, group 18 responds the same as group 17 (see
"Appendix B, Table B1 "Sensor Group Characteristics").
Note
For UL Listed installations, Alarm Verify must be set to off.
49
WWW.DIYALARMFORUM.COM
Reporting-Partition 1-6 (Default = off)
To turn Latchkey Format off or on:
1.
With the desired partition selected,
press A or B until the display shows
LATCHKEY FORMAT OFF/ON
setting).
2.
Press 1 (off—basic) or 2 (on—
advanced). The display flashes the
entered setting. Press # and the dis-
play shows the new setting.
Reporting-Partition 1-6 (Default = off)
To turn Freeze Alarm reporting off or on:
1.
With the desired partition selected, press A or B
until the display shows
(current setting).
2.
Press 1 (off) or 2 (on). The display flashes the
entered setting. Press # and the display shows
the new setting.
Reporting-Partition 1-6 (Default = 42
To set the Freeze Temp:
1.
With the desired partition selected, press A or B
until the display shows
setting).
2.
Enter the desired temperature (40-90). The dis-
play flashes the entered setting. Press # and the
display shows the new setting.
Reporting-Partition 1-6 (Default = off)
To turn Alarm Verify off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2.
Press # and the display shows the new setting.
(current
FREEZE ALARM OFF/ON
°
F)
(current
FREEZE TEMP
ALARM VERIFY OFF/ON
Concord 4 Series Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

600-1021-95r600-1022-95r600-1040600-1042

Table of Contents