GE Concord 4 Series Installation Instructions Manual page 13

Security systems
Hide thumbs Also See for Concord 4 Series:
Table of Contents

Advertisement

Table 1: Maximum Device Wire Length and MIn./Max. Current Draw
Device
SuperBus 2000 2x16 LCD Alphanumeric Touchpad
SuperBus 2000 ATP 1000 Alphanumeric Touchpad
SuperBus 2000 ATP 2100 Alphanumeric Touchpad
SuperBus 2000 ATP 2600 Alphanumeric Touchpad
SuperBus 2000 GTS 50
SuperBus 2000 Fixed Display Touchpad
SuperBus 2000 RF Transceiver
SuperBus 2000 RF Receiver (see note)
SuperBus 2000 Phone Interface/Voice Module
SuperBus 2000 Voice Only Module
SuperBus 2000 2 Amp Power Supply
4 Input/2 Output SnapCard
8Z Hardwire Zone Expander SnapCard
4 Output SnapCard
SuperBus 2000 8Z Input Module
SuperBus 2000 4-Relay Output Module
SuperBus 2000 Energy Saver Module
SuperBus 2000 Cellular Backup Module
SuperBus 2000 Automation Module
SuperBus 2000 Wireless Gateway-Ready Kit
Interrogator 200
Interrogator AVM
2-Wire Smoke Detectors (ESL 429AT, 521B, 521BXT)
2-Wire Smoke Detectors (System Sensor 2400, 2400TH)
Hardwire Interior Siren (13-949)
Piezo Dynamic Exterior Siren (13-950)
Concord 4 Series Systems
Table 1 describes the maximum wire length allowed between compatible devices and the panel,
and the minimum and maximum current draw of each device.
WWW.DIYALARMFORUM.COM
Max. Wire Length
Standby mA
to Panel
Draw
22 ga.—300 ft.
15 mA
18 ga.—750 ft.
22 ga.—300 ft.
12 mA
18 ga.—750 ft.
22 ga.—300 ft.
30 mA
18 ga.—750 ft.
22 ga.—300 ft.
30 mA
18 ga.—750 ft.
22 ga.—100 ft.
270 mA
18 ga.—250 ft.
22 ga.—300 ft.
11 mA
18 ga.—700 ft.
22 ga.—1,000 ft.
45 mA
18 ga.—2,500 ft.
22 ga.—1,100 ft.
35 mA
18 ga.—2,800 ft.
22 ga.—40 ft.
25 mA
18 ga.—120 ft.
22 ga.—40 ft.
20 mA
18 ga.—120 ft.
no load
N/A
20 mA
N/A
38 mA
N/A
1 mA
22 ga.—1,800 ft.
18 mA
18 ga.—4,000 ft.
22 ga.—350 ft.
12 mA
18 ga.—900 ft.
22 ga.—1,600 ft.
20 mA
18 ga.—4,000 ft.
Standard Power:
22 ga.—15 ft.
90 mA
18 ga.—40 ft.
High Power
22 ga.—10 ft.
90 mA
18 ga.—30 ft.
22 ga.—1,500 ft.
30 mA
18 ga.—4,000 ft.
22 ga.—40 ft.
65 mA
18 ga.—90 ft.
22 ga.—3,200 ft.
10 mA
18 ga.—4,500 ft.
22 ga.—110 ft.
45 mA
18 ga.—260 ft.
22 ga.—330 ft.
70 µA
18 ga.—330 ft.
22 ga.—330 ft.
120 µA
18 ga.—330 ft.
22 ga.—750 ft.
0 mA
18 ga.—1,500 ft.
22 ga.—750 ft.
0 mA
18 ga.—1,500 ft.
Alarm mA Draw
90 mA
110 mA
165 mA
165 mA
300 mA
65 mA
55 mA
35 mA
600 mA
300 mA (jumper)
600 mA (no jumper)
no load
185 mA*
230 mA*
130 mA*
35 mA
180 mA
20 mA
1600 mA
1900 mA
35 mA
1600 mA
10 mA
300 mA
60 mA
80 mA
85 mA
150 mA
8