Multi-Partition Arm/Disarm (0005)

Controls which partitions can be armed/disarmed simultaneously when using a
touchpad and access code assigned to those partitions. When enabled, users can
arm/disarm selected partitions using an authorized access code. When disabled,
multiple partitions cannot be armed/disarmed simultaneously.
At least two partitions must be selected for this feature to work.
Touchpads must be assigned to at least one of the selected partitions of this
menu for this feature to work.
Access codes must be assigned to all selected partitions of this menu for
this feature to work. If the partition assignment for a specific access code
does not match the partitions selected in this menu, only those partitions
common to both menu settings can be armed/disarmed simultaneously
with that code.
A partition cannot be armed/disarmed if it is being controlled by another
source at that time.
All arming modifiers (No Delay, Latchkey, etc.) except Silent affect all
partitions being armed. Only the arming partition can be armed silently.
When arming multiple partitions, any conditions that prevent arming
(open sensor, trouble, active alarm, etc.) are identified on touchpad dis-
plays with the affected partition number flashing. The normal protest/auto
force arm sequence follows, or pressing * cancels the arming request.
When disarming multiple partitions, any partitions in alarm have the
affected partition number flashing on touchpad displays. Pressing # can-
cels all alarms in the selected partitions. Alarm memory information is
then displayed for all canceled alarms.
Concord 4 Series Systems
WWW.DIYALARMFORUM.COM
Security-Global (Default = none)
To enable Multi-Partition Arm/Disarm:
1. With the display showing
, press 1-6 to enter the
ARM/DISARM _
desired partitions (at least two). The dis-
play flashes the entered partitions.
2. Press # and the display stops flashing.
To disable Multi-Partition Arm/Disarm:
1. With the display showing
ARM/DISARM n n n n n n n
displayed partitions by entering the
appropriate partition number. The parti-
tion numbers disappear from the display.
2. Press #.