Note
For UL 1635 installations,
Entry Delay plus Dialer
Abort Delay must not
exceed 60 seconds.
3
The following table describes non-programmable (hard coded) system operation as required to
meet ANSI-SIA CP-01 and is provided only for your reference.
Function
SIA False Alarm
Auto Stay Arming
Disarm During Entry Delay
Cancel Alarm
Abort Annunciation
Entry/Exit Progress Annunciation
Note
Silent arming feature may be used to supress arming level and exit beeps for the current arming period
only. Refer to user guide for more information on silent arming.
Commercial Burglary Alarm System Unit (Grade B UL 1610)
Basic system using Control Panel 600-1040, SuperBus 2000 RF Transceiver Module (600-1025-
01-95R), plus:
•
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/Window
Sensor (60-499)
•
SAW PIR Sensor (60-639-95R), Crystal PIR Sensor (60-703-95R), or DS924i PIR Sensor
(60-511-01-95)
•
UL Grade A Bell/Housing such as Ademco #AB12M or equivalent
•
Immediate Beeps set to on
•
UL 98 Options set to on
•
Receiver Failure set to on (if wireless devices are used)
•
RF TX Timeout set to 4 hours
•
24-Hour Tamper set to on
•
System Tamper set to on
•
Auto Phone Test set to on
•
Phone Test Freq. set to 1
•
Next Phone Test set to 1
•
Siren Verify set to on
•
AC Failure set to on
•
Exit Delay set to 120 seconds or less
•
Quick Exit set to off
•
Two Trip Error set to off
•
Alarm Verify set to off
•
Disable Trouble Beeps set to off
•
Phone Number must be programmed
•
High Level Rpts set to on
•
Low Level Rpts set to on
•
Comm. Failure set to on
•
Extended Delay set to off
•
Sleep Time set to off
•
Siren Timeout set to 4 minutes or more
UL 1610 24-Hour Backup
•
Same as UL 1023 & 985
UL 1635 Digital Alarm Communicator System
Same as UL 1023, 985 & 1610 plus:
•
AC Failure set to on
•
Phone Number must be programmed
•
Low CPU Battery set to on
•
Next Phone Test set to 1
WWW.DIYALARMFORUM.COM
Operation
Enabled
Enabled
Enter Code Only (or 1 + CODE)
Enter Code Only (or 1 + CODE)
Enabled
Enabled
Concord 4 Series Systems