Reset Modes
The TLP 710CV has four reset modes that correspond to four of the five reset modes for
the IP Link controllers. The modes are initiated by pressing the Reset button.
To access the Reset button on the TLP 710CV, remove the faceplate.
Mode Activation
1
Hold down the recessed Reset
button while applying power to the
TLP 710CV.
NOTE:
is performed, update the
TLP 710CV firmware to the
latest version. Do not operate
the firmware version that
results from this mode reset.
To use the factory default
firmware, reload that version.
See page 25 for details about
uploading
3
Hold down the Reset button for
approximately 3 seconds until the
Release LED blinks once. Then release
and press Reset momentarily (less
than 1 second) within 1 second.
4
Hold down the Reset button for
approximately 6 seconds until the
Release LED blinks twice (at 3 seconds
and 6 seconds). Then release and
press Reset momentarily (less than
1 second) within 1 second.
NOTE:
5
Hold down the Reset button for
approximately 9 seconds until the
Release LED blinks three times (at 3,
6, and 9 seconds). Then release and
press Reset momentarily (less than
1 second) within 1 second.
NOTE:
TLP 710CV Reset Mode Summary
Result
The TLP 710CV reverts to the factory default
firmware. Event scripting does not start if the
TLP 710CV is powered on in this mode. All user
files and settings (drivers, adjustments, IP settings,
etc.) are maintained.
After a mode 1 reset
NOTE:
firmware.
This mode turns events on or off.
NOTE:
This mode:
•
•
•
•
Nothing happens if the
•
momentary press does not
•
occur within 1 second.
•
This mode performs a complete reset to
factory defaults (except the firmware). It does
everything that mode 4 does and, in addition:
•
•
•
Nothing happens if the
•
momentary press does not
occur within 1 second.
If you do not want to update firmware
or you performed a mode 1 reset by
mistake, cycle power to the TLP 710CV
to return to the firmware version that
was running before the mode 1 reset.
Use the 0Q SIS command to confirm that
the factory default firmware is no longer
running (look for asterisks following the
version number).
Nothing happens if the momentary
press does not occur within 1 second.
Enables ARP capability.
Resets the IP address to the factory default
(192.168.254.254).
Resets the subnet to the factory default.
Resets the gateway address to the factory
default.
Resets port mapping to the factory default.
Turns DHCP off.
Turns events off.
Removes button and touchpanel
configurations.
Resets all IP options
Removes all scheduling options.
Removes and clears all files from the
TLP 710CV.
TLP 710CV • Reset Modes
Purpose and
Notes
This mode reverts to the
factory default firmware
version if incompatibility
issues arise with
user-loaded firmware.
NOTE:
User-defined
web pages
may not work
correctly if using
an earlier version
of the firmware.
This mode is useful for
troubleshooting.
This mode enables
you to set IP address
information, using ARP
and the MAC address.
This mode is useful
to start over with
configuration and
uploading. It also allows
you to replace events.
43
Need help?
Do you have a question about the TLP 710CV and is the answer not in the manual?
Questions and answers