Connecting Power

ATTENTION:
Do not power on the touchpanels until you have read the Attention in the "Rear Panel Features" section of the TLP Pro
1225, 1525, and 1725 Series User Guide.
Ne branchez pas les écrans tactiles avant d'avoir lu la mise en garde dans la section « Rear Panel Features » du
TLP Pro 1225, 1525, and 1725 Series User Guide.
The TLP Pro 1725MG ships with the Extron PI 140 power injector included. For the TLP Pro 1225MG and TLP Pro 1525MG, the
power injector must be purchased separately. Figure 4 shows the PI 140. Your power injector may look different.
Connect a straight-through Ethernet cable from the power injector to a switch or
1.
1
router (see figure 4,
or router to the power supply input.
Connect a second straight-through cable (
2.
TLP Pro touchpanel XTP/LAN/PoE connector (see
This cable carries the network information and 48 VDC from the power injector
to the touchpanel.
Connect the IEC power cord to a convenient 100 VAC to 240 VAC, 50-60 Hz
3.
power source (figure 4,
Alternatively, use an Ethernet cable to connect the XTP/LAN/PoE port of the interface
to a PoE+ switch or connect the touchpanel directly to an XTP model that is capable
of remotely powering a touchpanel (see the

Reset Modes: a Brief Summary

These touchpanels offer the following reset modes. For full information about the modes, see the TLP Pro 1225, 1525, and 1725
Series User Guide.
Use factory firmware:
Reset All IP Settings:
Reset to Factory Defaults: Use this mode to return the interface to factory default settings. Press and hold the RESET
Enable or Disable the
DHCP Client:
). This cable carries network information from the switch
2
) from the power injector to the
figure 3
3
).
note
on page 4).
Use this mode to replace firmware in the event of firmware failure. Press and hold the RESET
figure 3
button (see
,
Use this mode to reset all network settings without affecting user-loaded files. Press and
hold the RESET button for 6 seconds. After the RESET LED (
momentarily press the RESET button.
button for 9 seconds. After the RESET LED blinks three times, release and momentarily press
the RESET button.
NOTES:
The factory configured passwords for all accounts on this device have been set to the
device serial number. Passwords can be changed during configuration. Passwords are
case sensitive.
If the device is reset to default settings, the passwords are reset to the default
password, which is extron (for either admin or user ).
Use this mode to toggle between DHCP enabled and DHCP disabled.
Press the RESET button five times, consecutively. After the fifth press, do not press the button
again within 3 seconds. If DHCP was enabled, it is now disabled and the RESET LED blinks
three times. If DHCP was disabled, it is now enabled and the RESET LED blinks six times.
NOTES:
By default DHCP is off and the unit uses a static IP address.
When you disable the DHCP client, the unit reverts to using the previously-set static IP
address.
I
,
, on page 4).
C
) while applying power to the unit.
Product Category
100-240V~50/60 Hz
1.1A MAX
INPUT
OUTPUT
LAN
POWERED TLP
3
Extron PI 140
1
To a TLP Pro
To Network or
touchpanel
XTP Device
Figure 4.
Connecting the Power Injector
B
) blinks twice, release and
2
5