3.11.2 Applied motor (Pr. 71, Pr. 450
Set the motor used.
When using an other manufacturer's motor, set "3" or "13" in Pr.71 and perform offline auto tuning. Refer to the
Instruction Manual (basic) for the motor setting, etc.
Parameter
Name
71
Applied motor
450
Second applied motor
<Setting>
• Refer to the following table and set this parameter according to the motor used.
Setting
0
Mitsubishi standard motor (SF-JR)
3
4
5
Other manufacturer's s
6
7
8
Mitsubishi constant-torque motor
10
(SF-HRCA)
13
14
15
Other manufacturer's c
motor
16
17
18
20
SF-JR (4P)-1.5kW or less
23
(during vector control)
24
30
(factory setting)
SF-V5RU dedicated motor
33
(including SF-VR type motor)
34
CAUTION
1. Refer to page 120 for offline auto tuning.
2. Refer to page 39 for details of setting conventional Mitsubishi motors and other manufacturer's
motors.
Set this parameter correctly according to the motor used.
REMARKS
•
For online auto tuning, refer to the Instruction Manual (basic).
Operation selection function 2 (Pr. 65 to Pr. 79)
speed
Factory Setting
30
9999
Motor
Inverter internal constants
Offline auto tuning
Offline auto tuning data utilization
Star connection direct input
tandard motor
Delta connection direct input
Star connection direct input + offline auto tuning
Delta connection direct input + offline auto tuning
Inverter internal constants
Offline auto tuning
Offline auto tuning data utilization
Star connection direct input
onstant-torque
Delta connection direct input
Star connection direct input + offline auto tuning
Delta connection direct input + offline auto tuning
Inverter internal constants
Offline auto tuning
Offline auto tuning data utilization
Inverter internal constants
Offline auto tuning
Offline auto tuning data utilization
CAUTION
111
)
torque
position
Setting Range
0, 3 to 8, 10, 13 to 18,
20, 23, 24, 30, 33, 34
0, 10, 30, 9999
Control Constants
Remarks
9999: Second applied
motor invalid
3