Using The Pu Connector For Computer Link - Mitsubishi Electric FR-V500 Instruction Manual

High precision & fast response vector inverter
Hide thumbs Also See for FR-V500:
Table of Contents

Advertisement

1.6.9

Using the PU connector for computer link

(1) When connecting the control panel or parameter unit using a connection cable
Refer to the Instruction Manual (basic).
(2) For RS-485 communication
The PU connector can be used to perform communication operation from a personal computer etc.
When the PU connector is connected with a personal, FA or other computer by a communication cable, a user
program can run and monitor the inverter or read and write to parameters.
<PU connector pin-outs>
Viewed from the inverter (receptacle side) front
CAUTION
1. Do not connect the PU connector to the computer's LAN board, FAX modem socket or telephone
modular connector. Otherwise, the product may be damaged due to electrical specification
differences.
2. Pins No. 2 and 8 (P5S) provide power to the control panel or parameter unit.
Do not use these pins for RS-485 communication.
<System configuration example>
(1) Connection of a computer to the inverter (1:1 connection)
Computer
RS-485
Interfase
terminal
Computer - inverter connection cable
For a connection cable between the computer having RS-232C and the inverter (RS-232C⇔RS-485
converter), refer to the table below.
Examples of commercially available products (as of September, '06)
Type
FA-T-RS40 type*
* The converter cable cannot connect two or more inverters (the computer and inverter are connected on a 1:1
basis). Since the product is packed with the RS-232C cable and RS-485 cable (10BASE-T + RJ-45 connector),
the cable and connector need not be prepared separately. Contact a maker for details of the product.
REMARKS
When fabricating the cable on the user side, see below.
Examples of commercially available products (as of September, '06)
Product
1)
10BASE-T cable
2)
RJ-45 connector
8)
1)
Station 0
Inverter
RS-232C
RS-485
connector
cable
RJ-45
connector 2)
10BASE-T cable 1)
Mitsubishi Electric Engineering Co., Ltd
Type
SGLPEV-T 0.5mm × 4P
* Do not use No. 2 and No. 8 pin (P5S).
5-554720-3
1) SG
5) SDA
2) P5S
6) RDB
3) RDA
7) SG
4) SDB
8) P5S
Station 0
Computer
Inverter
RS-232C
connector
RS-485
connector
Maximum 15m
RS-232C
RS-485
converter
10BASE-T cable 1)
Maker
Maker
Mitsubishi Cable Industries, Ltd.
Tyco Electronics Corporation
23
Others
RJ-45 connector 2)
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-v520Fr-v540