Display functions 1 (Pr. 52 to Pr. 56)
Pr. 52
Signal
Display
Type
Unit
DU LED
Regenerative
0.1%
9
brake duty
Electronic
overcurrent
0.1%
10
protection
load factor
Output
current
0.01A
11
peak value
Converter
output
0.1V
12
voltage
peak value
Input
×
terminal
——
status
Output
×
terminal
——
status
Load meter
0.1%
17
*1
Motor
excitation
0.01A
18
current
Position
——
19
pulse
Cumulative
1h
20
energization
time
Reference
×
——
voltage
output
Actual
operation
1h
23
time
Motor load
0.1%
24
factor
Torque
0.1%
32
command*1
Torque
current
0.1%
33
command*1
Motor
0.01
34
output *1
kW
Feedback
——
35
pulse
Parameter Settings
Pr. 53 Pr. 54 Pr. 158
DA1
DA2
PU main
PU level
terminal
terminal
monitor
meter
12 bits
12 bits
(±10V)
(+10V)
*2
9
9
*2
10
10
*2
11
11
*2
12
12
×
×
*2
×
×
*2
17
17
17
18
18
18
×
×
19
×
×
20
×
×
21
×
×
23
×
×
24
×
32
32
×
33
33
×
34
34
×
×
35
Full-Scale Value
of the Level
± Output
Meter Connected
to DA1 and DA2
×
Pr. 70
Thermal relay
×
operation level
×
Pr. 56
×
400V/800V
×
——
×
——
Pr. 866
×
Pr. 56
×
——
×
——
×
——
×
——
×
——
Pr. 866
Pr. 866
Rated motor
current
×
——
98
Description
The brake resistor duty is
displayed.
The thermal relay load factor is
displayed.
The peak value of the output
voltage is displayed as effective
value.
The peak value of DC bus voltage
is displayed.
————
————
The load meter is output.
Pre-excitation current is displayed.
The position of the motor output
shaft is monitored.
Cumulative energization time since
the inverter shipment (power on
time) is displayed. (Minimum
increment is Hr)
The voltage of DA1 and DA2 at full-
scale is output
The inverter running time is
accumulated. (The time during a
stop is not accumulated.)
It is cleared using Pr. 171 "actual
operation hour meter clear".
The load factor to the rated motor
capacity is displayed.
The torque command value is
displayed.
The torque current command value
is displayed.
The machine output of the motor
shaft end is displayed.
The number of pulses feed back
during 1 sampling is displayed.
Display range is 0 to 99999 pulses.
Sampling time for the following
number of encoder pulses are:
1.0s for 1500 pls/rev or less;
0.5s for 1501 to 3200 pls/rev; and
0.25s for 3201 to 4096 pls/rev.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-v520Fr-v540

Table of Contents