How to use the output signals (assigned terminals
DO1 to DO3, ABC) (Pr. 190 to Pr. 192, Pr. 195)
Setting
Signal
Positive
Negative
Name
logic
logic
32
132
Y32
33
133
RY2
34
134
LS
35
135
TU
36
136
Y36
37
137
MT
39
139
Y39
40
140
Y40
41
141
FB
42
142
FB2
43
143
FB3
44
144
RUN2
96
196
REM
97
197
ER
98
198
LF
99
199
ABC
9999
——
0 to 99: Positive logic, 100 to 199: Negative logic
Function
Regenerative status
For vector control
output
Output on completion of pre-excitation. Turned on at an output start when pre-
Operation ready 2
excitation is not made.
Low speed output
Output when the speed falls to or below any preset low speed.
Output when the motor torque rises above the predetermined value (Pr.864).
Torque detection
(Refer to page 182.)
In-position
Acts as an in-position signal.
Maintenance timer
Refer to Pr. 890 to Pr. 892 (maintenance output function) (page 187).
output
Start time tuning
Output on completion of start time tuning
completion
Trace status
Acts as a trace completion signal.
Speed detection
Output when the motor output speed (feed back value) exceeds the preset
Second speed
detection
speed.
Perform in the same way as FU, FU2 and FU3 under V/F control.
Third speed
detection
• Output during forward rotation or the reverse rotation signal is on.
• Output at deceleration even during forward rotation or the reverse rotation
signal is off. (Does not output during pre-excitation LX is on.)
Inverter running 2
• Output during the orientation command signal (X22) is on.
• Switched on when the servo is on (LX-on) under position cotrol. (Switched
off when the servo is off. (LX-off)
Remote output
Refer to Pr. 495 to Pr.497 (page 168).
At occurrence of a major fault, the base circuit is shut off immediately. At
Minor fault output 2
occurrence of a minor fault, the base circuit is shut off after deceleration to a
stop.
Minor fault output
Output when a minor fault (fan fault or communication error alarm) occurs.
Output when the inverter's protective function is activated to stop the output (major
Alarm output
fault).
No function
Operation
36