At-a-glance guide to functions
Function
Brake sequence
Torque bias
Regenerative function selection
Soft-PWM
Torque characteristic selection
Encoder rotation direction
Number of encoder pulses
Conditional position control by contact input
Direct display and direct setting of motor constants
Speed setting/display unit switchover
Electronic gear
Multi-function input terminal assignment
Analog input assignment/calibration
Analog command filter time constant
Override, polarity reversible
Output stop
Multi-function output terminal assignment
Speed limit output
Inverter running signal
Up-to-speed signal
Overload alarm signal
Speed detection signal
Regenerative brake prealarm signal
Electronic thermal relay function prealarm signal
PU operation mode signal
Operation ready signal
Output current detection signal, zero current detection
signal
Fan fault output signal
Fin overheat prealarm signal
Forward, reverse rotation output signal
Regenerative status output signal
Operation ready 2 signal
Low speed detection signal
Torque detection signal
Maintenance output
Remote output
Instantaneous power failure (undervoltage) signal
Fault definition
Minor fault output signal
Alarm output signal
DU/PU display data selection
DA1, DA2 output/calibration
DA1 output filter
Running speed monitor
Output current monitor/output current peak value
monitor
Output voltage monitor
Preset speed monitor
Output frequency monitor
Motor torque monitor
Converter output voltage monitor, converter output
voltage peak value monitor
Pr. number
Pr. 60, Pr. 278 to Pr. 285
Pr. 180 to Pr. 183, Pr. 187, Pr. 840
to Pr. 848, Pr. 904, Pr. 905
Pr. 30, Pr. 70
Pr. 240
Pr. 801
Pr. 852
Pr. 851
Pr. 465 to Pr. 494
Pr. 71, Pr. 82, Pr. 90 to Pr. 94, Pr. 859
Pr. 37, Pr. 144, Pr. 81, Pr. 454, Pr. 505,
Pr. 811
Pr. 420, Pr. 421, Pr.505, Pr.811
Pr. 180 to Pr. 183, Pr. 187
Pr. 868 / Pr. 902 to Pr. 920
Pr. 822, Pr. 826, Pr. 832, Pr. 836
Pr. 73, Pr. 252, Pr. 253
Pr. 17, Pr. 180 to Pr. 183, Pr. 187
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 13, Pr.190 to Pr. 192, Pr. 195
Pr. 41, Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 42, Pr. 43, Pr. 50, Pr. 116,
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 150, Pr. 151, Pr. 152, Pr. 153,
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195, Pr. 865
Pr. 190 to Pr. 192, Pr. 195, Pr. 864
Pr. 190 to Pr. 192, Pr. 195,
Pr. 890 to Pr. 892
Pr. 190 to Pr.192, Pr. 195,
Pr. 495 to Pr. 497
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195, Pr. 875
Pr. 190 to Pr. 192, Pr. 195
Pr. 190 to Pr. 192, Pr. 195
Pr. 52, Pr. 53
Pr. 54 to Pr. 56, Pr. 866, Pr. 158,
Pr. 900, Pr. 901
Pr. 867
Pr. 52 to Pr. 55, Pr.158
Pr. 52 to Pr. 54, Pr. 56, Pr. 158
Pr. 52 to Pr. 54, Pr. 158
Pr. 52 to Pr. 55, Pr. 158
Pr. 52 to Pr. 55, Pr. 158
Pr. 52 to Pr. 54, Pr. 158, Pr. 866
Pr. 52 to Pr. 54, Pr. 158
74
Vector with encoder
Control
Speed
Torque
SF-V5RU
"Motor with encoder (standard,
Applicable
constant torque)"
*: This function can be usable under
Motor
position control by parameter
setting.
Terminal
X42, X43
×
×
Terminals 1, 2, 3
MRS
×
SL
RUN
SU
OL
FU, FU2, FU3
FB, FB2, FB3
RBP
THP
PU
RY
Y12, Y13
FAN
FIN
Y30, Y31
Y32
RY2
LS
TU
MT
REM
IPF
ER
LF
ABC
DA1, DA2
DA1
Position
×
×
×
×
×
×
×
×
×
×
×
×
×