Display Function 3 (Pr. 160); Extended Function Display Selection (Pr. 160); Initial Monitor (Pr. 171); Actual Operation Hour Meter Clear (Pr. 171) - Mitsubishi Electric FR-V500 Instruction Manual

High precision & fast response vector inverter
Hide thumbs Also See for FR-V500:
Table of Contents

Advertisement

Display function 3 (Pr. 160)

3.18 Display function 3 (Pr. 160)
3.18.1 Extended function display selection (Pr. 160
Used to display the extended function parameters.
Refer to page 66 for the extended function parameter list.
Parameter
Name
Extended function
160
selection
Pr. 162 to Pr. 165
Refer to Pr. 57 (page 101).

3.19 Initial monitor (Pr. 171)

3.19.1 Actual operation hour meter clear (Pr. 171
You can clear the actual operation hour of the monitoring function.
Parameter
Name
Actual operation hour
171
meter clear
<Setting>
Write "0" in the corresponding parameter to clear the actual operation hour.
REMARKS
The actual operation time is the value monitored by setting "23" in Pr. 52.
Related parameters
• Pr. 52 "DU/PU main display data selection" (Refer to page 97.)

3.20 Terminal assignment functions (Pr. 180 to Pr. 195)

3.20.1 Input terminal function selection
(Pr. 180 to Pr. 183, Pr. 187
Use these parameters to select/change the input terminal functions.
Parameter
Name
DI1 terminal
180
function
selection
DI2 terminal
181
function
selection
DI3 terminal
182
function
selection
DI4 terminal
183
function
selection
STR
terminal
187
function
selection
Factory
Setting
Setting
Range
0
Factory Setting
0
speed
Terminal
Factory-
Factory-Set Terminal
Symbol
Set Value
Low speed operation
DI1
0
command (RL)
Middle speed
DI2
1
operation command
(RM)
High speed operation
DI3
2
command (RH)
Second function/
DI4
3
second motor
switchover (RT)
Reverse rotation
STR
9999
command (STR)
speed
0
Only the simple mode parameters are accessible.
1
All parameters are accessible.
speed
Setting Range
0
)
torque
position
Setting
Function
Range
0 to 3, 5, 8 to
12,14 to 16,
20, 22 to 28,
42 to 44,
9999
150
)
torque
position
Remarks
)
torque
position
Remarks
9999: No function
9999: STR
Extended
mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-v520Fr-v540

Table of Contents