Utilizing Or Changing Offline Auto Tuning Data For Use - Mitsubishi Electric FR-V500 Instruction Manual

High precision & fast response vector inverter
Hide thumbs Also See for FR-V500:
Table of Contents

Advertisement

5)
When tuning was ended forcibly
Tuning is ended forcibly by pressing
In this case, offline auto tuning has not ended properly.
(The motor constants have not been set.)
Perform an inverter reset and restart tuning.
REMARKS
1. The motor constants measured once in the offline auto tuning are stored as parameters and their data are held until the
offline auto tuning is performed again.
2. An instantaneous power failure occurring during tuning will result in a tuning error. After power is restored, the inverter
goes into the ordinary operation mode. Therefore, when STF (STR) is on, the motor runs in the forward (reverse) rotation.
3. Any alarm occurring during tuning is handled as in the ordinary mode. Note that if an error retry has been set, retry is
ignored.
4. The set speed monitor displayed during the offline auto tuning is 0r/min.
Note that the motor may start running suddenly.
When the offline auto tuning in the rotation mode is used in vertical lift application, e.g. an elevator, it
may drop due to insufficient torque.

3.12.4 Utilizing or changing offline auto tuning data for use

<Setting the motor constants as desired>
Pr. 90 to Pr. 94 (motor constants) may be set as desired in either of two ways; the data measured in the offline auto
tuning are read and utilized or changed, or the motor constants are set without the offline auto tuning data being
used.
<Operating procedure>
1. Set the following value in Pr. 71 :
• Mitsubishi standard motor............................................................................. Pr. 71 = "4"
• Mitsubishi constant-torque motor.................................................................. Pr. 71 = "14"
• Mitsubishi standard motor SF-JR (4P) (1.5kW or less) ................................ Pr. 71 = "24"
• SF-V5RU, SF-VR.......................................................................................... Pr. 71 = "34"
2. Set "801" in Pr. 77.
(The parameter values of Pr. 82 "motor excitation current" and Pr. 90 to Pr. 94 (motor constants) can be
displayed. Though the parameter values of other than Pr. 82 and Pr. 90 to Pr. 94 can also be displayed, they
are parameters for manufacturer setting and their values should not be changed.)
3. In the parameter setting mode, read the following parameters and set desired values.
Parameter Number
82
Motor excitation current (no load current)
90
Motor constant R1
91
Motor constant R2
92
Motor constant L1
93
Motor constant L2
94
Motor constant x
859
Torque current
REMARKS
When "0" (factory setting) is set in Pr. 684 "tuning data increment switchover", the motor constants are set in "internal variable
increment". When "1" is set in Pr. 684, the motor constants are set in "mH,
4. Return the Pr. 77 setting to the original value.
REMARKS
1. Set "9999" in Pr. 90 to Pr. 94 to use the standard motor constants (including those for the constant-torque motor).
2. Set "3 (standard motor), "13" (constant-torque motor) or "23" (Mitsubishi standard SF-JR(4P) 1.5kW or less) in Pr. 71 to
use the constants measured in the offline auto tuning. Set "4, 14 or 24" in Pr. 71 and change the motor constants to
change the values measured in the offline auto tuning.
3. As the motor constants measured in the offline auto tuning have been converted into internal data (****), refer to the
following setting example when making setting:
Setting example: To slightly increase Pr. 90 value (5%)
When Pr. 90 is displayed "2516", set 2642, i.e. 2516 × 1.05=2641.8, in Pr. 90. (The value displayed has been converted
into a value for internal use. Hence, simple addition of a given value to the displayed value has no significance.)
4. When "1" is set in Pr. 96, the last values of Pr. 82, Pr. 92, and Pr. 93 remain unchanged.
STOP
or turning off the start signal (STF or STR) during tuning.
RESET
CAUTION
Name
Setting Range Setting Increments Factory Setting
0 to ****, 9999
0 to ****, 9999
0 to ****, 9999
0 to ****, 9999
0 to ****, 9999
0 to ****, 9999
0 to ****, 9999
123
Offline auto tuning (Pr. 80 to Pr. 96)
1
1
1
1
1
1
1
Ω
, A". (can be set when Pr. 77 = "801")
9999
9999
9999
9999
9999
9999
9999
3