3.5.4
S-pattern acceleration/deceleration curve (Pr. 29, Pr. 140 to Pr. 143, Pr. 380 to
Pr. 383
speed
When you have changed the preset speed during start, acceleration, deceleration, stop, or operation, you can
change the running speed by acceleration/deceleration to make adjustment to reach the preset speed. Set
the acceleration/deceleration pattern in Pr. 29 "acceleration/deceleration pattern".
Parameter
Name
Acceleration/
29
deceleration pattern
Backlash acceleration
140
stopping speed
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping speed
Backlash deceleration
143
stopping time
380
Acceleration S pattern 1
381
Deceleration S pattern 1
382
Acceleration S pattern 2
383
Deceleration S pattern 2
Operation selection functions 1 (Pr. 17 to Pr. 37)
torque
)
Factory
Setting Range
Setting
0
30r/min
0 to 3600r/min
0.5s
0 to 360s
30r/min
0 to 3600r/min
0.5s
0 to 360s
0%
0 to 50%
0%
0 to 50%
0%
0 to 50%
0%
0 to 50%
89
0
Linear acceleration/deceleration
1
S-pattern acceleration/deceleration A
2
S-pattern acceleration/deceleration B
Backlash measures acceleration/
3
deceleration
4
S-pattern acceleration/deceleration C
Accessible when Pr. 29 = 3
Accessible when Pr. 29 = 4
Remarks