Mitsubishi Electric FR-V500 Instruction Manual page 142

High precision & fast response vector inverter
Hide thumbs Also See for FR-V500:
Table of Contents

Advertisement

7)
Sum check code
The sum check code is 2-digit ASCII (hexadecimal) representing the lower 1 byte (8 bits) of the sum (binary)
derived from the checked ASCII data.
(Example 1)
Computer
Inverter
ASCII code
*
: When the Pr. 123 "waiting time setting" setting is other than 9999, create the communication request
data without "waiting time" in the data format. (The number of characters decreases by 1.)
(Example 2)
Inverter
Computer
ASCII code
8)
Error code
If any error is found in the data received by the inverter, its definition is sent back to the computer together with
the NAK code. (Refer to page 137.)
CAUTION
1. When the data from the computer has an error, the inverter does not accept that data.
2. All data communication, e.g. run command or monitoring, are started when the computer gives a
communication request. The inverter does not return any data without the computer's request. For
monitoring, etc. therefore, design the program to cause the computer to provide a data read request
as required.
Communication functions (Pr. 117 to Pr. 124, Pr. 342)
*
Station
Instruction
Waiting
ENQ
number
code
time
0
1
E
1
1
H05
H30 H31
H45 H31
H31
H30 H37 H41 H44 H46 H34
H
H
H
H
H
H
H
+
+
+
+
+
+
30
31
45
31
31
30
37
H
= 1F4
Sum
Station
STX
Read data
number
0
1
1
7
7
H02
H30 H31
H31 H37
H37
H30 H03 H33 H30
H
H
H
H
H
H
+
+
+
+
+
30
31
31
37
37
30
H
= 130
Sum
133
Sum check
Data
code
0
7
A
D
F
4
Binary code
H
H
+
+
41
44
Sum check
ETX
code
0
3
0
Binary code
3